IES-0920 User Manual
Page 4
Product Highlights
Basic Features
•
Meets NEMA TS1/TS2 Environmental requirements such as temperature, shock, and
vibration for traffic control equipment.
•
Meets EN61000-6-2 & EN61000-6-3 EMC Generic Standard Immunity for industrial
environment.
•
UL1604 Class I, Division 2 classified for use in hazardous locations (applicable to
versions with terminal block power option).
•
Supports 802.3/802.3u/802.3X.
•
Auto-negotiation: 10/100Mbps, full/half-duplex. Auto MDI/MDIX.
•
Supports 2048 MAC addresses.
•
Provides 768K bits memory buffer.
•
Alarms for power and port link failure by relay output 1.5A @ 24VDC.
•
Operating voltage and Max. current consumption: 0.76A @ 12VDC, 0.38A @ 24VDC,
0.19A @ 48VDC. Power consumption: 9.12W Max.
•
Power Supply: Redundant DC Terminal Block power inputs or 12VDC DC JACK with
100-240VAC external power supply.
•
Field Wiring Terminal: Use Copper Conductors Only, 60/75
℃
, 12-24 AWG torque value 7
lb-in.
•
-40
℃
to 75
℃
(-40
℉
to 167
℉
) operating temperature range. Tested for functional
operation @ -40
℃
to 85
℃
(-40
℉
to 185
℉
). UL1604 Industrial Control Equipment
certified Maximum Surrounding Air Temperature @ 74
℃
(165
℉
).
•
Supports DIN-Rail or Panel Mounting installation.