Power connection

 

 

This unit provides 4 pin terminal block. It can be operated using 48-56VDC power 

source. Always Make sure your input voltage is within this supported voltage 
range. You need to use 56VDC input to generate IEEE802.3at 30Watts power.

 

 

To make power connection – Follow the printed polarity for V+, V- and RLY. 

Connect positive wire to V+, connect negative wire to V- and also connect neutral 
wire to ground.  

 

+V-

 is for power input connection, this unit has only one power input.

 

RLY

 is for relay connection. 

 

 

 

 
 

 
 
 

 

Connecting procedure:

 

STEP 1 –

 

Take out 4 pin terminal block located in the included mounting kit package.

 

STEP 2 – 

 

Connect power wire to +V- with correct polarity. Connect RLY for relay.  

 

STEP 3 –

 

Plug into terminal block socket shown above. Polarity needs to match the V+ and V-

 

 

WARNING -- Always SHUTS OFF power source to connect power wire.

 

WARNING -- Any exceeded input voltage will not make this unit function 

and may damage this unit.

 

 

 

LED indicator

 

 

LED

 

Color

 

State

 

Description

 

PWR

 

Green

 

ON

 

Power is detected

 

OFF

 

Power is not detected

 

SFP Lnk/Act

 

Green

 

ON

 

FX port is detected

 

Flashing

 

FX data is transmitting/receiving

 

TX Lnk/Act

 

Green

 

ON

 

TX link is detected

 

Flashing

 

TX data is transmitting/receiving

 

TX PoE

 

Amber

 

ON

 

PSE is activated and PD is detected

 

OFF

 

PSE is detecting PD

 

 

 

+V1-  RLY

 