3
Power connection
This unit provides 4 pin terminal block. It can be operated using 48-56VDC power
source. Always Make sure your input voltage is within this supported voltage
range. You need to use 56VDC input to generate IEEE802.3at 30Watts power.
To make power connection – Follow the printed polarity for V+, V- and RLY.
Connect positive wire to V+, connect negative wire to V- and also connect neutral
wire to ground.
+V-
is for power input connection, this unit has only one power input.
RLY
is for relay connection.
Connecting procedure:
STEP 1 –
Take out 4 pin terminal block located in the included mounting kit package.
STEP 2 –
Connect power wire to +V- with correct polarity. Connect RLY for relay.
STEP 3 –
Plug into terminal block socket shown above. Polarity needs to match the V+ and V-
WARNING -- Always SHUTS OFF power source to connect power wire.
WARNING -- Any exceeded input voltage will not make this unit function
and may damage this unit.
LED indicator
LED
Color
State
Description
PWR
Green
ON
Power is detected
OFF
Power is not detected
SFP Lnk/Act
Green
ON
FX port is detected
Flashing
FX data is transmitting/receiving
TX Lnk/Act
Green
ON
TX link is detected
Flashing
TX data is transmitting/receiving
TX PoE
Amber
ON
PSE is activated and PD is detected
OFF
PSE is detecting PD
+V1- RLY
Summary of Contents for IGC-0101