LED Indicators 

 
The diagnostic LEDs located on the front panel of the industrial switch provide 
real-time information of system and optional status. The following table provides the 
description of the LED status and their meanings for the switch. 
 

LED 

Color 

Description 

On 

Power input 1 is active 

P1 Green 

Off 

Power input 1 is inactive 

On 

Power input 2 is active 

P2 Green 

Off 

Power input 2 is inactive 

On 

Power input 1 or 2 has failed 

Fault Red 

Off 

Power input 1 and 2 are both functional, 
or no power inputs 

On 

The port is supplying power to the 
powered-device 

FWD 
(1 ~ 4) 

Green 

Off 

No powered-device attached or power 
supplying fails 

On Connected 

to 

network 

Flashing 

Networking is active 

Green 
(Upper LED) 

Off 

Not connected to network 

On Full-duplex 

link 

Flashing Collision 

occurs 

1 ~ 5 
(RJ-45) 

Yellow 
(Lower LED) 

Off 

Half-duplex link or link down 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

8

Summary of Contents for IFE-0500

Page 1: ...LevelOne IFE 0500 4 Port PoE 1 Port TP Industrial Fast Ethernet Switch User Manual Ver 1 0 0 0711 1...

Page 2: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged...

Page 3: ...EL 6 TOP VIEW 7 LED INDICATORS 8 PORTS 9 CABLING 11 WIRING THE POWER INPUTS 12 WIRING THE FAULT ALARM CONTACT 13 MOUNTING INSTALLATION 14 DIN RAIL MOUNTING 14 WALL MOUNT PLATE MOUNTING 16 HARDWARE INS...

Page 4: ...er the RJ 45 cable Features System Interface Performance y RJ 45 ports support Auto MDI MDI X Function y Embedded 4 port PoE Injection y Store and Forward Switching Architecture y Back plane Switching...

Page 5: ...ist IFE 0500 CD Manual Pluggable Terminal Block attached on the switch 2 wall mount plates with screws One DIN Rail attached on the switch Compare the contents of the industrial switch with the standa...

Page 6: ...installation will be described Physical Dimension 4 Port PoE 1 Port TP Industrial Fast Ethernet Switch dimension W x D x H is 30mm x 95mm x 140mm Front Panel The Front Panel of the 4 Port PoE 1 Port T...

Page 7: ...Top View The top view of the 4 Port PoE 1 Port TP Industrial Fast Ethernet Switch has one terminal block connector of two DC power inputs Top View of the IFE 0500 Industrial Fast Ethernet Switch 7...

Page 8: ...1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 has failed Fault Red Off Power input 1 and 2 are both functional or no power inputs On The port i...

Page 9: ...ir All ports on this industrial switch support automatic MDI MDI X operation user can use straight through cables See figure below for all network connections to PCs or servers or to other switches or...

Page 10: ...Straight Through Cable Schematic Cross Over Cable Schematic 10...

Page 11: ...ded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 100Base TX standard for Category 5 The cable between the converter and the link partner switch hub wo...

Page 12: ...Please follow the steps below to insert the power wire Insert the positive and negative wires into the V and V contacts on the terminal block connector Tighten the wire clamp screws for preventing th...

Page 13: ...n the wires are inserted into ports 3 and 4 they automatically detect the fault status in the event of a power failure by forming an open circuit An example for the fault alarm contact is shown as bel...

Page 14: ...itch please see the following pictures to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch 1 Use the screws to screw the DIN Rail on the rear side of the industria...

Page 15: ...4 Then lightly push the DIN Rail into the track 5 Check if the DIN Rail is tightened on the track or not 6 To remove the industrial switch from the track reverse steps above 15...

Page 16: ...emove the DIN Rail 3 Place the wall mount plate on the rear panel of the industrial switch 4 Use the screws to screw the wall mount plate on the industrial switch 5 Use the hook holes at the corners o...

Page 17: ...refer to the Mounting Installation section 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the power The power LED on...

Page 18: ...Network Application This segment provides the sample to help user have more actual idea of industrial switch application For a sample application of the industrial switch see the figure below 18...

Page 19: ...y twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators the Switch can be easily monitored through panel indicators which describes common problems user may encounter a...

Page 20: ...ocol CSMA CD Transfer Rate 14 880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX Fast Ethernet port MAC Address 1K MAC address table LED Per unit Power 1 Green Power 2 Green Fault Red Per p...

Page 21: ...ounting Operating Temp 10 to 60 14 140 Operation Humidity 5 to 95 Non condensing Storage Temperature 40 to 85 Case Dimension IP 30 30 mm W x 95 mm D x 140mm H EMI FCC Class A CE EN61000 4 2 3 4 5 6 8...

Reviews: