background image

3-2 

Workstation Problems 

Most non-cabling problems result from improper configuration of the network 
interface card (NIC) and its corresponding driver. The following points will be 
helpful: 

• 

Like other add-on cards in the workstation or server, NIC must have unique 

memory address, I/O address, and interrupt. The settings on a particular card 
must not conflict with the settings on any other card in the same station. 
Please refer the User's manual of the NIC, computers, and Networking 
operating systems to determine the proper configuration 

• 

The selection of half or full duplex, the speed of 10 or 100Mbps for the NIC 

setting must match the mode and speed setting of the corresponding port of 
the Hub. For NWay Auto-Negotiation setting, both link partners will auto-adjust 
to the highest allowable speed and mode operation

 

Other Problems 

Other specific problems may be diagnosed by using the LEDs, as below. 

Power LED is off when the AC Power switch is ON: 

• 

Defective power supply unit or fuse 

• 

Incorrect AC voltage 

• 

Defective Hub 

Link/Act LED is off at any Fiber: 

• 

Faulty node or wiring connection  
For fiber -  the "TX", "RX" cables should be paired at both ends 
 No Link signal is received from the remote node/site 

100Base-X Port at irregular traffic: 

• 

Abnormal or invalid transmission status(mode / speed) between local and 
remote link partners, i.e., full-duplex port is connecting to a half-duplex port, 
or 10Mbps port is connecting to a 100Mbps device 

Hub Diagnostic Test 

 

The switch hub performs self-diagnostic test at major hub modules upon 
power on, LED indicators will go to normal status if no problem occurred 

 

To reset or restart the hub, power off the hub and wait for 10 seconds, then 
power on it again 

Summary of Contents for FSW-0800FXC

Page 1: ...LevelOne FSW 0800FXC FSW 0800FXT FSW 1600FXC FSW 1600FXT 8 16 Port 100Mbps Fast Ethernet Switch with SC ST Connector User s Guide...

Page 2: ...ations Commission FCC Statement This equipment has been tested and found to comply with the limits for a class A computing device pursuant to Subpart J of part 15 of FCC Rules which are designed to pr...

Page 3: ...2 Installing Network Connection 2 1 Installation 2 1 Network Parameter for 100Mbps Fiber 2 1 Switch Hub Cascading and Long Haul Connection 2 2 Fiber Port Full Half duplex DIP Switch Setup 2 3 LED Ind...

Page 4: ...1600FXC 16 Port 100Mbps Fast Ethernet Switch with SC Connector FSW 1600FXT 16 Port 100Mbps Fast Ethernet Switch with ST Connector Models Description Configuration 16 Fiber 8 Fiber 100FX Fiber Jack 16...

Page 5: ...b is powered off wait at least 10 seconds before powering it on again Network Parameter for 100Mbps Fiber To help ensure a successful installation you must observe the following cabling parameter Viol...

Page 6: ...ot work and other 100Base X ports on the hub are functioning remove a fiber plug from a functioning port with a functioning workstation workstation B and insert it into the suspect port If workstation...

Page 7: ...uplex Network Interface 16ST M Sixteen ST multi mode fiber ports 16SC M Sixteen SC multi mode fiber ports 16SC S Sixteen SC single mode fiber ports Cable and Maximum length 50 125 62 5 125 or 100 140m...

Page 8: ...f duplex Network Interface 8ST M Eight ST multi mode fiber ports 8SC M Eight SC multi mode fiber ports 8SC S Eight SC single mode fiber ports Cable and Maximum length 50 125 62 5 125 or 100 140mm mult...

Page 9: ...tners will auto adjust to the highest allowable speed and mode operation Other Problems Other specific problems may be diagnosed by using the LEDs as below Power LED is off when the AC Power switch is...

Page 10: ...vel 1 hub and connect all other hubs to it at Level 2 Server Host is recommended to connect to the Level 1 hub By following this approach it will minimize the number of hubs in any one path and will i...

Page 11: ...and select the DIP switch Level 2 8 port Fiber Switch Long Haul Intra hub connection Level 2 16 Port Fiber ST SC Switch Fig 2 1 Multiple Hubs Cascading and Long Haul Connection Default FDX HDX 2 1 4 5...

Page 12: ...2 4 mode setting Then power on to restart the new configuration and status...

Page 13: ...e device is good Blinks when any traffic is present 100Mbps Green Lit when 100Mbps speed is active FDX Col Amber Lit when full duplex mode is active Blinks when any collision signal is present Table 2...

Page 14: ...ing Hub Link Act 100Mbps F D X C o l P O W E R 1 2 3 4 5 6 7 8 1 MPR 2 3 4 5 6 7 8 1 DTE TX RX TX RX FDX HDX A B A B A B Link Act 100M bps FD X C ol POW ER Link Act 100M bps FD X C ol 10 100 Switching...

Reviews: