LevelOne FHU-0803TXD Manual Download Page 6

 

6

 

N o t e s :

 1.  Make sure each  twisted-pair cable does not exceed 100 meters 

 (328 feet).

 

              2. The Category 5 cables are used for all Fast Ethernet 

connections. We advise using Category 5 cable for dual-
speed hub to avoid any confusion or inconvenience in 

the future when you upgrade attached devices to Fast 
Ethernet.

 

3.  When a hub is to be connected to another switch in a daisy-

chain configuration, set the port 8 as daisy -chain port (Swit ch 

MDI-X/MDI to right position).  Use normal RJ45 cable.  Plug 
one end of the cable into port 8 of the hub and plug the other 

end of the cable into any port of the other switch.   

Note:

  When switch MDI-X/MDI set to MDI, the port 8 of the unit 

cannot be used as a station port. 

4.  When external switch device is adopted to interconnect other 

segments, the switch on the left side panel of FHU-0803TXD 

can set the port 8 as 10Mbps port in case both interconnected 
ports are auto-negotiated. 

5.  Plug the power cord into the corresponding socket.  

Then connect it to an electrical outlet to power on the 
hub.  

Troubleshooting 

The hub can be easily monitored through panel indicators to assist 

the network manager in identifying problems.  This section 
describes common problems you may encounter and possible 

Summary of Contents for FHU-0803TXD

Page 1: ...ontains two internal repeater buses one for 10 Mbps traffic and another for 100 Mbps traffic Traffic passing between attached devices that operate at the same speed is confined within the appropriate...

Page 2: ...nels the data to the appropriate backplane which is the 10 or 100 Mbps repeater bus The FHU 0803TXD contains a 2 port switch to connect these two repeater buses The learning function of the internal s...

Page 3: ...ion port plus the overall condition affecting the hub LED Color Indication Power POWER Green ON Unit is receiving power OFF Power is disconnected no power received Collision COL Orange ON Collision ha...

Page 4: ...Port is in 100 Mbps connection OFF Port is in 10 Mbps connection Switch Position There is a switch MDI X MDI on the front side Make sure the switch is in the correct position Switch Position Indicatio...

Page 5: ...should be located in a cool dry place with at least 10 cm 4 in of space at the front and back for ventilation Place the hub out of direct sunlight and away from heat sources or areas with a high amou...

Page 6: ...nto port 8 of the hub and plug the other end of the cable into any port of the other switch Note When switch MDI X MDI set to MDI the port 8 of the unit cannot be used as a station port 4 When externa...

Page 7: ...after making a connection Cause Network interface network cable or hub port is defective Solution Verify that the hub and attached device are powered on Be sure the cable is plugged into both the hub...

Page 8: ...lded twisted pair shielded twisted pair Interfaces 8 RJ 45 station ports 1 RJ 45 daisy chain MDI port Hub to Workstation Distance 100 meters maximum using category 5 UTP or STP cable Indicator Panel L...

Page 9: ...CSA NRTL T V GS Switching Criteria Network Bridging Function filtering forwarding and learning Switching Method store and forward Address Table 1K entries Queue Buffer 120KB Buffer per port Filtering...

Reviews: