Extraordinary maintenance
The machine extraordinary maintenance (e.g. replacement of actuator, electrical parts, rollers, wheels, belts, bearings,
...) must be carried out by qualified personnel.
It is recommended that extraordinary maintenance, that falls outside the provisions of chapter 4, is carried out by
personnel authorised by Levante. It is forbidden to carry out any extraordinary maintenance, repair or replacement,
without the direct consent of the manufacturer. If necessary, contact your distributor.
Parts subject to wear and, therefore, potentially subject to extraordinary maintenance are:
-
Lifting belt: regularly check the tension and mechanical consistency of the belt.
-
Teflon sliding rollers inside the aluminium mast: check the status and wear and keep the sliding channels
lubricated.
-
Front and pivoting wheels: replace when worn.
-
Worm screw pinion: it wears over time and it must be replaced at an assistance centre.
-
Forks: periodically check the thickness of the forks, if it reduces by 0.5 mm compared to the initial 60 mm,
replace the forks unit.
-
Parking brake: periodically check the efficiency of the parking brake. If the efficiency showed it was unable to
stop the forklift on a gradient of at least 5%, replace the wheels complete with brake.
Use only original spare parts supplied by the manufacturer (see section "SPARE PARTS").
7.
Troubleshooting
These cases fall within the competence of maintenance personnel.
NUMBER
FAULT
CAUSE
SOLUTION
1
The machine will not
turn on
1.
Power supply problem
1.
Check the internal
protection fuse
2.
Check the state of the
batteries
2
The forks do not stop
at the maximum and
minimum height
1.
Incorrect position of the limit switches
1.
Check the limit switch
micros located in the top
and bottom parts of the
mast
3
The forks are not lifted
1.
The load exceeds the maximum
capacity allowed
1.
Check the load weight and
reduce it if necessary
4
The lifting motor does
not start
1.
Emergency stop engaged, power supply
suspended
2.
Voltage too low
3.
The electric cable connectors are
disconnected
4.
Faulty motor contactor
1.
Turn clockwise to restore
power supply
2.
Charge
3.
Fix them
4.
Replace it
5
The batteries do not
recharge
1.
The current socket is disconnected
2.
Fault on charging circuit
3.
Old batteries
1.
Reconnect it
2.
check the fuse on the
charger board;
3.
check the efficiency of the
batteries and replace them
if necessary