background image

Leuze electronic GmbH + Co. KG

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

KRT18BW. …2… 

[email protected]  •  www.leuze.com

Part number code

K R T 1 8 B W . H 2 / G 6 T - M 1 2

Operating principle
KRT

Contrast sensor

Series
18B

18B series

Light source
W

White light

Light spot orientation
H

Horizontal (transverse)

V

Vertical (lengthwise)

Setting
2

Multiturn potentiometer with bar graph signal display, light/dark switching via button

Pin assignment of connector pin 4 / black cable wire (OUT1)
G

Push-pull switching output, PNP dark switching (dark on), NPN light switching (light on)

Pin assignment of connector pin 2 / white cable wire (OUT2)
6

Push-pull switching output, PNP light switching (light on), NPN dark switching (dark on)

Pin assignment of connector pin 5 / gray cable wire (IN)
T

Input for light/dark switching and locking of the operational controls

Connection technology
M12

M12 connector, 5-pin

KRT18BW

White light contrast sensor

Summary of Contents for KRT18BW

Page 1: ...trol cable Blocking of all operational controls via con trol cable Accessories available separately Mounting systems BTU 200M BT 95 Mounting adapter for standard design 80 mm x 53 mm x 30 mm BTX 018M...

Page 2: ...t temp operation storage 40 C 60 C 40 C 70 C Protective circuit 3 3 2 polarity reversal protection 3 short circuit protection for all transistor outputs 2 3 VDE protection class 4 4 Rating voltage 50V...

Page 3: ...r with bar graph signal display light dark switching via button Pin assignment of connector pin 4 black cable wire OUT1 G Push pull switching output PNP dark switching dark on NPN light switching ligh...

Page 4: ...er code Part no Features KRT18BW H2 G6T M12 50147611 Light spot orientation horizontal transverse antivalent push pull outputs potentiometer with bar graph Selectable additional function light dark sw...

Page 5: ...he mark under the light spot If the bar graph indicator is to the right of the middle position turn the multiturn potentiometer counterclockwise until the sensor switches on yellow indicator LED Q1 on...

Page 6: ...tton longer than 12s Release the button To change the setting again push the button again for longer than 12 s and release Only the green LED flashes 1 Only for devices without analog output 12s L D R...

Page 7: ...switching light on OUT1 Locking all operational controls via the IN input Pin 5 A static HIGH signal 20ms at the IN input Pin 5 locks all operational controls on the sensor if required such that no ma...