![Leuze it 3820 User Manual Download Page 8](http://html1.mh-extra.com/html/leuze/it-3820/it-3820_user-manual_1883782008.webp)
2014/07
Connecting the IT 3820 to the PS/2 interface
The operation of the IT 3820 in keyboard emulation mode is described in this section. A PC keyboard is emulated in this operating
mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further
in all standard programs.
required parts:
1x
501 06 242
IT 3820 SR 0C0BE
1x
501 03 990
Base station ST 2020
1x
501 03 989
Power supply unit ST 2020
1x
501 03 409
PS/2 cable
Procedure:
1.
Switch off the PC.
2.
Disconnect the keyboard.
3.
Connect the cable for the ST 2020 base sta-
tion between the keyboard and the PC.
4.
Switch the PC back on.
5.
Scan the barcodes shown below.
6.
Return the IT 3820 to the base station to apply
the settings. This procedure is concluded with
audible confirmation signals.
IBM PCs and compatible PCs, postfix
Keyboard layout for Germany/Austria
Notice!
To charge the IT 3820, the power supply unit must be plugged in and the hand-held scanner placed in the ST 2020
base station.
Disconnect