![Leuze DCR 258i Original Operating Instructions Download Page 65](http://html1.mh-extra.com/html/leuze/dcr-258i/dcr-258i_original-operating-instructions_1883777065.webp)
Starting up the device – Basic configuration
Leuze electronic GmbH + Co. KG
DCR 258i
65
8.6
Performing further settings
8.6.1
Decoding and processing the read data
The device offers the following possibilities:
• Setting the number of code labels to be decoded for each reading gate (0 … 99). This is done via the
Max. no. of labels
parameter.
• Setting the
Search mode
in which the system is to search for the codes (see chapter 8.6.5 "Optimizing
•
Fast
•
Optimized
•
Robust
• Further parameters can be set for many code types, e.g.
• Code type (symbology)
• Number of digits
Either a number of digits, e.g., 10, 12, 24, or a number of digits range, e.g., 8 … 22
• Check digit method used for decoding as well as the type of check digit transmission for the output
of the read result.
Standard: corresponds to the standard for the selected code type/symbology
Not standard
Ä
Define at least one code type with the desired settings.
ð
webConfig tool:
Configuration > Decoder
ð
Control buttons (not on devices wit stainless steel housing):
AUTO
function
8.6.2
Control of the decoding
In general, decoding is controlled via the configurable switching inputs/outputs. The corresponding connec-
tion to the PWR / SWIO interface must be configured as a switching input for this purpose (see chapter 7.2
"PWR / SWIO").
Controlling decoding via a switching input:
• Start/stop decoding
• Start decoding and then stop decoding after a configurable time period
• Read in a reference code
• Start automatic code type configuration (
AUTO
function)
• Start alignment mode
Ä
Connect the required control devices, e.g., photoelectric sensor, proximity switch, etc., to the device
(see chapter 7 "Electrical connection").
Ä
Configure the connected switching inputs according to your requirements.
ð
First set the I/O mode to input.
ð
Then configure the switching behavior.
ð
webConfig tool:
Configuration > Control > Digital I/Os
NOTICE
Alternatively, depending on the camera operating mode, you can activate decoding using the
+
online command and deactivate it using the
–
online command (see chapter 11.1 "Online com-