Mounting and commissioning
Leuze electronic GmbH & Co. KG
CSL 505
21
4
Mounting and commissioning
Legend:
1
M8 connector/connection cable
2
Front screen
3
Aluminum housing
4
First beam
5
Last beam
Figure 4:
Mounting the CSL 505 switching light curtain
You will find the dimensions in: Table 13: "Dimensions CSL 505" on page 34 or Table 14: "Dimensions
of CSL 505, special variant "VB"" on page 36.
NOTE
•
Do not mechanically load, bend or warp the bars.
•
Protect the cable from being crushed and from exposure to strong electromagnetic
effects.
•
Increased risk of soiling if mounted horizontally! Dirt and liquids on the front
screen can be detected as an object and may penetrate into the device.
•
Mount the transmitter and receiver at the same height or with the same housing
reference edge, free of tension and with the base in full contact with the mounting
surface.
•
The optical surfaces of transmitter and receiver must be parallel to and opposite
one another.
•
The transmitter and receiver connections must point in the same direction.
•
For horizontally mounted measuring light curtains with lengths of more than
2,000 mm, use an additional mounting bracket in the middle of the light curtain.
•
Secure transmitter and receiver against turning or sliding.
•
No reflective surfaces, no mutual interference!
•
There must be no reflecting surfaces near the light curtain. Otherwise objects may
not be detected due to the reflection.
•
Avoid influences caused by other optical sensors through suitable positioning and
partitioning.
•
Avoid strong extraneous light effect (caused for example by strobe lights, direct
sunshine) on the receiver bar.