Device parameters and interfaces
Leuze
electronic
80
BPS 34
Leuze electronic
8.1.7.23 Module 22: Velocity measurement control
Description
The control manages the timing of the velocity measurement by starting or stopping the
measurement function. Control is performed depending on certain events such as the
switching input, time functions or PROFIBUS output bits. Using parameters, it determines
the events which influence the states.
Parameter
Hex coding of module 22 "Velocity measurement"
The value listed in the table shows the hex coding of the default settings.
Parameter
Description
Rel.
addr.
Data
type
Value range
Defaul
t
Unit
CR to
module
Velocity
measure-
ment start
mode
The start mode determines by
which event the velocity meas-
urement is started.
0
unsign
8
0: Deactivated
1: After initialisation
2: Following event:
either by the switching input
or by a signal from the
PROFIBUS master
0
–
7 g
Velocity
measure-
ment stop
mode
The stop mode determines after
which event the velocity meas-
urement is stopped.
1
unsign
8
0: Deactivated
1: By an error
2: By a stop event:
either by output bit 0.1 or by
the switching input function
0
–
7 g
Parameter length: 2 byte
a
b
Internal ad
dress
of mod
u
le 22
V
e
locity measurement
star
t mo
de
ad
d
ress 0
V
e
locity measurement
s
top mode
ad
d
ress 1
18
00
00