Starting up the device - Configuration
Leuze electronic
BCL 604i
62
Parameter
Table 10.12:
Parameters for module 11
Parameter length
6 byte
Input data
None
Output data
None
10.7.3 Module 12 – Multi-label
Description
The module permits the definition of multiple bar codes with a different number of digits and/or code types
in the reading gate and provides the necessary input data.
Parameter
Description
Addr.
Data type
Value range
Default Unit
Automatic reading
gate repeat
The parameter defines the automatic repeat of
reading gates.
0
Byte
0: No
1: Yes
0
-
Reading gate end
mode/completeness
mode
This parameter can be used to configure the
completeness inspection.
1
Byte
0: Independent of decod
-
ing, i.e., the reading gate
is not terminated prema
-
turely.
1: Dependent on decod
-
ing, i.e, the reading gate is
terminated if the config
-
ured number of bar codes
to be decoded has been
reached.
a)
2: DigitRef table-depen
-
dent, i.e., the reading gate
is terminated if each bar
code stored in the code
type table has been
decoded.
b)
3: Ident list dependent,
i.e., the reading gate is
terminated if each identi
-
fier stored in a list could
be segmented via a
respective bar code seg
-
mentation.
c)
4: Reference code com
-
parison, i.e., the reading
gate is terminated if a pos
-
itive reference code com
-
parison has taken place.
d)
1
-
Restart delay
The parameter specifies a time after which a
reading gate is restarted. The device gener
-
ates its own periodic reading gate.
The configured time is active only if the auto
-
matic reading gate repeat is switched on.
2
UNSIGNED16 0 … 65535
0
ms
Max. reading gate
time when scanning
The parameter switches off the reading gate
after the set time has elapsed, thus limiting the
reading gate to the set period.
4
UNSIGNED16 1 … 65535
0: Reading gate deactiva
-
tion is switched off.
0
ms
a) see chapter 10.7.2 "Module 11 – Reading gate control"
b) Corresponds to the settings made via the device module (see chapter 10.4.4, see chapter 10.6.1).
c) see chapter 10.10, modules 52-54, identifier filter string