Example configurations
90
BCL 34
Leuze electronic
9.2
Direct Activation via the Switching Input
9.2.1
Task
• Reading of a 12-digit barcode in the 2/5 Interleaved format
• Direct activation of the BCL 34 via a photoelectric sensor
Code sample
Code 2/5 Interleaved 12 digits with check digit
‹8p"L6$›
561234765436
9.2.2
Procedure
Hardware, Connections
The following connections must have been established:
• Voltage supply (PWR)
• PROFIBUS In
• PROFIBUS termination
• Light barrier to SW IN
Modules Required
Include the following modules into your project:
•
12 byte (Module 23)
Parameter Settings
Byte
Description
Init value
Change value to:
2
[T1] digits 1
10
12
5
[T2] code type
Code 39
0 (no code)
9
[T3] code type
EAN8, EAN13
0 (no code)
13
[T4] code type
Code 128
0 (no code)
Table 9.1:
Device parameters for example configuration 2