PROFIBUS
54
BCL 34
Leuze electronic
Input Data
none
Output Data
none
8.3.5
EAN designator
Module 8
The module permits the search for an EAN128 field. The designator which is to be searched
for is specified in the parameter.
Parameters
Input Data
none
Output Data
none
Parameter
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
EAN 128-designator
The parameter specifies the EAN128
designator which is to be searched for,
i.e., the BCL provides only a result if the
designator has been found.
0 … 10,000
10,000
–
GPa,
1 … 4a
(Do not) output data
designator
Specifies whether the EAN 128 data
designator is included in the decoding
result or not.
0: not output
1: output
0
–
(Do not) output
symbology identifier
Specifies whether the EAN 128 symbol-
ogy identifier ([C1) is included in the
decoding result or not.
0: not output
1: output
1
–
Parameter length: 3 bytes