Commissioning steps at a glance
Leuze electronic
BCL 34
9
TNT
35/7-2
4
V
3
Commissioning steps at a glance
Notice!
Below you will find a
short description for the initial commissioning
BCL 34of the bar-
code reader. Detailed explanations for all listed points can be found throughout the manual.
Mechanical design
Mounting the device BCL 34
There are two different types of mounting arrangements for the BCL 34:
1.
Using 4 M4x6 screws on the rear of the device.
2.
Using a mounting device (BT 56) on the dovetail fastening grooves.
Notice!
The installation dimensions listed in the following figure must absolutely be adhered to.
Optically, it must be ensured that the scanner has an unobstructed view of the barcode at
all times. The scanning beam's angle of incidence on the label of at least 10° must be ad-
hered to.
Figure 3.1:
Beam exit and device arrangement of the BCL 34
Notice!
During installation, the working range of the reading field curve must be taken into account.
103 ± 2
10°
Read distance
Be
am
e
x
it
all dimensions
in mm
Scanning beam(s)