Configuration and diagnostics software - Sensor Studio
Leuze electronic GmbH + Co. KG
BCL 92
33
6.5.6
Switching input tab
NOTICE
The configuration options are identical for both switching inputs SWIN 1 and SWIN 2.
Fig. 6.12:
Switching input
tab
Inverted
Here, the input level can be inverted
Debounce time
This time period must lapse until the trigger signal is regarded as valid.
Start-up delay
(Start-up delay time)
The trigger signal is passed on delayed by the specified time period.
Pulse duration
If the value is higher than "0": duration of the activation, regardless of how
long the trigger signal has been applied.
Switch-off delay
(Delay off time)
After the end of the trigger signal, the pulse is extended internally by this
time period.
Function
(Control)
Event that is started when the switching input is activated.
NOTICE
If switch-off delay is activated, the
pulse duration
parameter should be "0".