Specifications
14
AMS 301
i
Leuze electronic
The AMS 301
i
is designed in accordance with safety class III for supply with
PELV (protective extra-low voltage).
Inputs/outputs
Quantity
Input
Output
2, programmable
protected against polarity reversal
max. 60mA, short-circuit proof
Mechanical data
Housing
cast zinc and aluminum
Optics
glass
Weight
approx. 2.45kg
Protection class
IP 65 acc. to EN 60529
3)
Environmental conditions
Operating temperature
without device heating
with device heating
-5°C … +50°C
-30°C … +50°C
4)
Storage temperature
-30°C … +70°C
Air humidity
max. 90% rel. humidity, non-condensing
Mechanical/electrical loading capacity
Vibrations
acc. to EN 60068-2-6
Noise
acc. to EN 60060-2-64
Shock
acc. to EN 60068-2-27
EMC
acc. to EN 61000-6-2 and EN 61000-6-4
5)
1)
Statistical error: 1 sigma; minimum switch-on time: 2min.
2)
For UL applications: only for use in "Class 2" circuits acc. to NEC.
3)
With screwed-on M12 plugs or mounted caps.
4)
With devices with heating, the switch on/off area of the internal heating can be extended to prevent
condensation from forming. A 100% prevention of the formation of condensation cannot be guaran-
teed due to the limited heating capacity of the AMS 301
i
.
5)
This is a Class A product. In a domestic environment this product may cause radio interference, in
which case the operator may be required to take adequate measures.