Setting the pulse stretching

If the web speed is high and the splice width is thin, the signal on the switching
output is very short when moving over a splice.

– Therefore a fixed pulse stretching of 20 ms is activated in the factory set-

tings.

– If pulse stretching is undesirable, you can switch the function off.

3

Ä

Press the teach button until the green ON LED and the yellow OUT LED flash
alternately.

Ä

Release the teach button.

ð

The green ON LED flashes for another 2 seconds and the yellow OUT LED
indicates the changed status of the pulse stretching for 2 seconds: 
OUT LED ON: pulse stretching activated 
OUT LED OFF: pulse stretching deactivated

Adjusting the switching behavior of the switching output (light/dark

switching)

4

Ä

Press the teach button until only the green ON LED flashes.

Ä

Release the teach button.

ð

The green ON LED flashes for another 2 seconds and the yellow OUT LED
indicates the changed switching behavior for 2 seconds: 
Yellow OUT LED ON: switching output, light switching (signal on the splice) 
Yellow OUT LED OFF: switching output, dark switching (signal on the web)

8

EN

Summary of Contents for 50142874

Page 1: ...14E SD Ultrasonic fork for splice detection Leuze electronic GmbH Co KG info leuze com In der Braike 1 73277 Owen Tel 49 7021 573 0 We reserve the right to make changes 2020 05 08 50143648 www leuze...

Page 2: ...1Figure part 1 2 2 7 s 3 7 12 s 2...

Page 3: ...4 12 s 5 2 s 2 s 6 7 s 3...

Page 4: ...7 A B T t HIGH LOW 20 ms 20 ms 8 4...

Page 5: ...ht switching signal on the splice Dark switching signal on the web Overview of the operating structure via the teach and minus buttons Function Configuration via buttons Standard function Normal opera...

Page 6: ...output 1 ON LED green Constantly ON when operating voltage is applied OUT LED yellow Indicates the switching signal LED is ON if the sensor detects the splice The display is independent of the output...

Page 7: ...sor during teach time the sensor calculates the switching threshold as a function of both states Advantage very reliable detection of splices If no splices are transported through the sensor during te...

Page 8: ...D flashes for another 2 seconds and the yellow OUT LED indicates the changed status of the pulse stretching for 2 seconds OUT LED ON pulse stretching activated OUT LED OFF pulse stretching deactivated...

Page 9: ...ce sensitivity Briefly press the minus button A single flash of the yellow OUT LED confirms button actuation Recommended settings Observation Measure Action After teaching the yellow LED and the switc...

Page 10: ...ionally trigger the easyTune function or the teaching of the device 6 Press the teach button and the minus button simultaneously until the green ON LED flashes at approx six times per second Release t...

Page 11: ...plied for at least 20 ms 7 A Buttons locked B Buttons can be operated T Duration of the teach signal Duration T ms Function 20 80 easy Teach with or without web transport 120 180 220 280 Configure the...

Page 12: ...also possible to lock the buttons via the teach input pin 5 A static high signal 20 ms on the teach input locks the buttons on the de vice so that no manual operation is possible The buttons can then...

Reviews: