Starting up the device - IO-Link interface
Leuze electronic GmbH + Co. KG
CML 730i
86
Blanking settings (group 8)
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
Trigger Settings
73
0
record 64 bit,
isolated
access to
sub-index not
possible
RW
Cascading
73
1
(bit
offset
= 56)
unsigned 8
RW
0 … 1
0
0: Not active (continuous scanning)
1: Active (sensor expects trigger signal)
Function type
73
2
(bit
offset
= 48)
unsigned 8
RW
0 … 1
0
0: Slave (expects trigger signal)
1: Master (sends trigger signal)
Trigger delay time →
Start measurement
73
3
(bit
offset
= 32)
unsigned 16
RW
500 … 65535 500
Unit: µs
Pulse width
73
4 (bit
offset
= 16)
unsigned_16 RW
100 … 65535 100
Unit: µs
Master cycle time
73
5
(bit
offset
= 0)
unsigned 16
RW
1 … 6500
1
Unit: ms
Up to 4 beam areas can be deactivated. Deactivated beams can be assigned the logical
values 0, 1 or the value of the adjacent beam. With auto blanking activated, up to 4 beam areas
are automatically suppressed during teaching.
Auto blanking should only be activated during commissioning of the light curtain to suppress
interfering objects. In process mode, auto blanking should be deactivated.
For details on this topic see chapter 15.4.
NOTICE
Perform teach after changing the blanking configuration!
Perform a teach after changing the blanking configuration.
A teach can be performed via the receiver control panel or via the teach command.
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
Blanking settings
76
0
record
208 bit, iso
-
lated access
to sub-index
not possible
RW
Number of auto blanking
areas
76
1
(bit
offset
= 200)
unsigned 8
RW
0 … 4
0
Permissible number of auto blanking areas
0: 0 auto blanking areas
1: 1 auto blanking area
2: 2 auto blanking areas
3: 3 auto blanking areas
4: 4 auto blanking areas
Auto blanking (during
teaching)
76
2
(bit
offset
= 192)
unsigned 8
RW
0 … 1
0
0: Not active (manual blanking area configuration)
1: Active (automatic area configuration through
teach)