Leuze
electronic
Communicating with the Device
Leuze electronic
VR 2300
51
TNT
35/7-2
4
V
9.3.16
Communication window
This panel permits the configuration of the setup interface and of the setup protocol.
Setup interface
Determines via which interface of the VR 2300 the Setup Tool can be
started. The choice includes COM1, COM2 and Ethernet.
Notice!
For the VR 2300, only the COM1 interface in connection with GModem protocol is suitable
as a setup interface.
Setup protocol
Determines the protocol that handles the communication with the Setup
Tool.
GModem
Handles the communication via the RS232 protocol without
hardware handshake.
SLIP
Transmits IP packets via the serial line using the SLIP
protocol.
PPP
Transmits IP packets via the serial line using the PPP
protocol.
Ethernet
Handles the communication via the Ethernet interface.