Electrical Installation
34
TMC 66
Leuze electronic
DEUTSCH
E
NGLISH
FRANÇAIS
IT
A
LIANO
ESPAÑOL
N
EDERLANDS
The signal output "Error" is always active if the TMC 66 detects an error. Those errors can
be internal or external. A detailed listing of all possible errors can be found in the next
chapter.
Through linking of the status outputs in the control unit, the following system states can be
detected:
1. "Safety on" active, "Error" inactive
Normal operation of the TMC 66, no error detected.
2. "Safety on" active, "Error" active
The TMC 66 has detected an error of the muting
lamps. In this case, the output "Error" only serves as
warning message and is reset after removal of the
failure.
3. "Safety on" inactive, "Error" active
The TMC 66 detected a safety relevant failure which
led to the switching off of the safety outputs.