4.2.2.3
Receiver Extended, LED displays and protective field states when the internal
start/restart interlock function is activated:
The following illustrations show the behaviour of the LEDs and OSSDs in start/restart
interlock operating mode.
LED1 LED2
Protective
field
Meaning
green OFF
free
LED1
green
=
OSSDs safety outputs in the ON state
LED2 OFF
=
Start/restart interlock not active, see Fig.
red
OFF
interrupted LED1 red
=
OSSDs safety outputs in the OFF state
LED2 OFF
=
Start/restart interlock not active.
As long as the protective field is interrup-
ted, it is not possible to start/restart the de-
vice, see Fig. 4.2-2 b
red
yellow
free
LED1 red
=
OSSDs safety outputs in the OFF state
LED2
yellow
=
Start/restart interlock active. The OSSDs
safety outputs are only turned on again af-
ter pressing and releasing the start/restart
button in a time window of 300 ms to 5 s,
Table 4.2-5:
Receiver Extended with selected internal start/restart interlock function
a
b
c
d
e
LED1: green
LED2: OFF
OSSDs: ON
LED1: red
LED2: OFF
OSSDs: OFF
LED1: red
LED2: yellow
OSSDs: OFF
LED1: green
LED2: OFF
OSSDs: ON
Fig. 4.2-2: