Allow for an optical and/or acoustic start warning.
Automatic start-up
The
automatic start-up
function starts the machine automatically as soon as the supply voltage is present.
Automatic restart
The
automatic restart
function starts the machine automatically as soon as the protective field is free again.
5.6.2 Start interlock/automatic restart
With start interlock/automatic restart, the safety sensor remains in the OFF state when, following a power
supply interruption, the voltage supply is restored. After violation of the protective field, the system restarts
when the protective field is free again.
The
start/restart interlock
has two functions:
• Start interlock
• Automatic restart
Using start interlock/automatic restart
In addition to the safety sensor you must also install the reset button. The machine operator starts the
machine with this reset button.
Position the reset button outside the danger zone so that it cannot be activated from the protective fields
and danger zones. The operator must be able to see all danger zones from this position.
Identify the area to be released on the reset button so that its meaning is clear and easy to understand.
Ensure that nobody is in the danger zone before pressing the reset button.
Hold down the reset button for between 0.12 s and 4 s to enable the safety-related switching outputs.
Start interlock
The
start interlock
function prevents the machine from starting automatically after switching on or after the
supply voltage returns.
The machine only starts when you press the reset button.
Automatic restart
The
automatic restart
function starts the machine automatically as soon as the protective field is free again.
5.6.3 Start/restart interlock (RES)
When accessing the protective field, the start/restart interlock ensures that the safety sensor remains in
the OFF state after the protective field has been cleared. It prevents automatic release of the safety circuits
and automatic start-up of the system, e.g. if the protective field is again clear or if an interruption in the
voltage supply is restored.
The
start/restart interlock
has two functions:
• Start interlock
• Restart interlock
Using start/restart interlock
In addition to the safety sensor you must also install the reset button. The machine operator starts the
machine with this reset button.
DANGER
Risk of death if start-up is operated unintentionally!
Ensure that the reset button for unlocking the start interlock cannot be reached from the danger zone.
Before unlocking the start interlock, make certain that no people are in the danger zone.
For access guarding, the start/restart interlock function is mandatory. The protective device may
only be operated without start/restart interlock in certain exceptional cases and under certain
conditions acc. to ISO 12100.