Leuze electronic PRK3CLA Autokollimation Manual Download Page 10

Function block Function

Description

Commands
The first four
commands
correspond to
the functions
which can be
performed at
the sensor us-
ing the teach
button or the
remote teach
function.

Sensitive teach
for the detection of
a transparent ob-
ject (e.g. empty sin-
gle bottle)

Clear the light path before activation.

Standard teach
for the detection of
a partially transpar-
ent object (e.g. bot-
tle made of colored
glass)

Clear the light path before activation.

Light switching

Dark switching

Switch the process
data display mode
to analog value

Activate to display diagrams on the 

Process

tab when using 

Sensor Studio configuration

software.

Laser safety notices - laser class 1

WARNING

LASER RADIATION – LASER CLASS 1

The device satisfies the requirements of IEC 60825-1:2007
(EN 60825-1:2007) safety regulations for a product of laser class 1 as
well as the U.S. 21 CFR 1040.10 regulations with deviations corre-
sponding to "Laser Notice No. 50" from June 24, 2007.

Ä

Observe the applicable statutory and local laser protection regula-
tions.

Ä

The device must not be tampered with and must not be changed
in any way.
There are no user-serviceable parts inside the device.

Ä

Repairs must only be performed by Leuze electronic GmbH + Co.
KG.

10

EN

Summary of Contents for PRK3CLA Autokollimation

Page 1: ...limation Laser retro reflective photoelectric sensors Leuze electronic GmbH Co KG info leuze com In der Braike 1 D 73277 Owen Tel 49 0 7021 573 0 We reserve the right to make changes 2018 10 50137135 01 www leuze com ...

Page 2: ...1Bildteil 1 LOW t 20 80 ms t HIGH A B C 2 LOW t 120 180 ms t HIGH A B C 3 LOW t 220 280 ms t HIGH 4 LOW t 320 380 ms t HIGH 5 2 ...

Page 3: ...6 A B 3 ...

Page 4: ...ating range factory setting 1 5 mm Standard teach low sensitivity 1 mm Sensitive teach increased sensitivity 0 1 0 2 mm 1 All specifications are typical values and may vary by a small amount for each unit Sensor adjustment teach via teach button The sensor is factory adjusted for maximum operating range The teach proce dure is only necessary if the sensor does not switch when an object enters the ...

Page 5: ...ng output ac tive if object in light path 2 Release teach button ready 2 Release teach button ready The sensor now operates with the maxi mum function reserve operating range Note The yellow LED is not dependent on the switching behavior setting and always indicates light switching in nor mal operation Device settings are stored fail safe Sensor adjustment teach via teach input pin 2 This device s...

Page 6: ...e when there is an ob ject currently in the light path With antivalent switching outputs OUT 1 pin 4 dark switching OUT 2 pin 2 light switching Locking the teach button via the teach input 5 This device setting is only available for sensors in the PRK3CL A3 T variant teach input via pin 2 A static high signal 20ms at the teach input locks the teach button on the sen sor if required such that no ma...

Page 7: ...s not interrupt this signal NOTICE In the Sensor Studio configuration software the following applies with regard to the designations Q1 OUT 1 Q2 OUT 2 The sensors offer no data retention and no ISDU support The device can only be identified via VendorID and DeviceID IO Link identification VendorID dec hex DeviceID dec hex Device 338 0x152 2119 0x000847 PRK3CL1 A3 LP IO Link process data Device out...

Page 8: ...s you will find the IODD zip file with all data required for the installation IO Link parameters documentation The complete description of the IO Link parameters can be found in the html files Double click on a language variant German IODD de html English IODD en html Functions configurable via IO Link PC configuration and visualization is performed comfortably with the USB IO Link Master SET US2 ...

Page 9: ...ng outputs Q1 and Q2 are antivalent switching outputs Light switching Q1 light switching Q2 dark switching Dark switching Q1 dark switching Q2 light switching Switching delay On activates the internal time function Function selection of the switching de lay Activation of a suitable switching delay is possible It is not possible to combine switching delays Time base of the switching delay Possibili...

Page 10: ...splay mode to analog value Activate to display diagrams on the Process tab when using Sensor Studio configuration software Laser safety notices laser class 1 WARNING LASER RADIATION LASER CLASS 1 The device satisfies the requirements of IEC 60825 1 2007 EN 60825 1 2007 safety regulations for a product of laser class 1 as well as the U S 21 CFR 1040 10 regulations with deviations corre sponding to ...

Reviews: