3.1.2.1 Bus termination
If the laser measuring device is the last
slave in the Profibus segment, the bus
line is to be terminated by the
termination switches = ON.
0 1
2
3
4
5 6 7
8
9
0 1
2
3
4
5 6 7
8
9
10
0
10
1
12
13
14
15
9 8 7 6 5
10
11
4 3 2 1
ON OFF
Termination
3.1.2.2 Bus addressing
Valid Profibus addresses: 3 – 99
10
0
: Setting of the units position
10
1
: Setting of the decimal position
12
13
14
15
9 8 7 6 5
10
11
4 3 2 1
ON OFF
Termination
0 1
2
3
4
5 6 7
8
9
0 1
2
3
4
5 6 7
8
9
10
0
10
1
3.1.3 SSI interface
Simultaneous use of the SSI- and Profibus DP - interface possible.
Pin 12
SSI-Clock +
Pin 13
SSI-Clock –
Pin 14
SSI-Data +
Pin 15
SSI-Data –
9 8 7 6 5
10
11
4 3 2 1
12
13
14
15
3.1.4 Switching input / Switching output
The programming of the switching input /switching output is carried out either directly
via the bus, or via the PC software "OMSConfiguration Tool".
Functions of the switching input:
-
Preset, - Switch off laser diode, - Failure quit
Functions of the switching output:
-
Temperature- , Intensity- , Hardware-Fail-Output or every fail
Pin 5
Switching
input
Pin 6
Switching
output
Pin 7
GND, reference potential pin 6
9 8
10
11
4 3 2 1
12
13
14
15
7 6 5