Integrating the LES in the process control
Leuze electronic
Technical description LES
103
TNT
35/7-2
4
V
10.3.3
User data in command mode (command parameters)
Set Laser Gate
For sensor control command 0x0001, one word of user data is transmitted to the sensor:
LF=0 switches the Laser off, LF=1 switches the laser on.
Set Actual Inspection Task
For sensor control command 0x004B, two words of user data are transmitted to the sensor:
If SF=0 then the inspection task is changed only temporarily.
If SF=1 then the newly set inspection task is retained even after a restart of the LES.
Get Actual Inspection Task
The LES responds to sensor control command 0x0049 with 0x004A and one word of user
data:
Byte
MSB
High-Byte
LSB MSB
Low-Byte
LSB Meaning of the bits
31…32
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LF
LF = Laser Flag
Byte
MSB
High-Byte
LSB MSB
Low-Byte
LSB Meaning of the bits
31…32
-
-
-
-
-
-
-
-
-
-
-
-
N4 N3 N2 N1 Number of the inspection task to be configured
(0 = Task0 … 15 = Task 15)
33…34
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SF
SF = SaveFlag
Byte
MSB
High-Byte
LSB MSB
Low-Byte
LSB Meaning of the bits
31…32
-
-
-
-
-
-
-
-
-
-
-
-
N4 N3 N2 N1 Number of the configured inspection task
(0 = Task0 … 15 = Task 15)