Leuze electronic HTU430B Series Quick Start Manual Download Page 5

Leuze electronic GmbH + Co. KG

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

HTU430B-…X3/LT4-M12 - 03

[email protected]  •  www.leuze.com

5

Adjustment of the switching points (Teach) using the control buttons

The two switching points of the sensor are both set to 3000mm or 6000mm (static 1-point teach) on delivery. 
By means of a simple operating procedure, the switching points for each output can be individually taught to an arbitrary distance 

within the operating range with 1-point teach (static) or 2-point window-teach (static). 
Moreover, the output function can be switched from NO contact (NO - normally open) to NC contact (NC - normally closed). A 

button is permanently assigned to each output for the setting (see dimensioned drawing).

Note!

All operating functions are identical for outputs OUT1 and OUT2.

Adjusting the switching function (NO/NC) using the control buttons

The control buttons can be used to switch the output function from NO contact to NC contact (or vice versa). 

To do this, proceed as follows:

Note!

For 2-point window-teach, the switching behavior is dependent on the selected object distances for switching points 1 

and 2. See previous page!

1-point teach (static)

2-point window-teach (static) 

1)

1) See table "Switching behavior with 2-point window-teach as a function of the switching function"

1.Place object at desired switching distance.

1.First, place object at desired switching distance for switching 

point 1.

2.To adjust output OUT1, press button 1, to adjust output 

OUT2, press button 2 for 2 … 7s until the yellow LED flashes 

at 3Hz.

2.To adjust output OUT1, press button 1, to adjust output 

OUT2, press button 2 for 7 … 12s until the yellow and green 

LED flash alternately at 3Hz.

3.Release the teach button to complete the teach event. 

The current object distance has been taught as the new 

switching point. 

3.Release the button. The sensor remains in teach mode and 

the LEDs continue to flash. 

4.Error-free teach: LED states and switching behavior accord

-

ing to the diagram shown above. 

Faulty teach (object may be too close or too far away – please 

note operating range): 

yellow LED flashes at 5Hz until an error-free teach event is 

performed.

The affected output is inactive as long as there is a teach 

error.

4.Then, place the object at the desired switching distance for 

switching point 2. 

Note:

the minimum distance between the switching points is as 

follows 

range of 3000mm:

250mm

range of 6000mm:

500mm

5.Briefly press the teach button again to complete the teach 

event. 

The switching window was taught in. 

6.Error-free teach: LED states and switching behavior accord

-

ing to the diagram shown above. 

Faulty teach (object may be too close or too far away – please 

note operating range): 

green and yellow LEDs flash at 8Hz until an error-free teach 

event is performed.

Action / Description

Control button

Indicator diode

GREEN

YELLOW

Changeover of the switching function:

Switching outputs OUT1 and OUT2 are set as NO contact 

ex works. If the switching function is changed, the 

respective switching output is changed to the opposite state 

(toggled).

Press the button for the desired 

switching output for longer than 

12s.

Both LEDs flash alternately for a 

short time at 3Hz. 

If the yellow LED is then ON, 

the output functions as an NO 

contact. 

If the yellow LED is then OFF, 

the output functions as an NC 

contact. 

HTU430B

ADVANCED ultrasonic sensors with 2 switching outputs

Summary of Contents for HTU430B Series

Page 1: ...design NEW Process data and configuration via IO Link interface NEW Five operating modes scanning synchronous multiplex activation and throughbeam operation 300 3000mm 600 6000mm 15 30 V DC Accessori...

Page 2: ...Ultrasonic transducer Piezoceramic 4 4 The ceramic material of the ultrasonic transducer contains lead zirconium titanate PZT Connection type M12 connector 5 pin Installation position Any Environment...

Page 3: ...X Advanced design 3 Teach button on the sensor Pin assignment of connector pin 4 black cable wire OUT1 4 PNP output NO contact preset P PNP output NC contact preset L IO Link communication or push pul...

Page 4: ...First taught object distance Second taught object distance Output switching behavior NO normally open NC normally closed Far Close Close Far Dead zone Sensor OUT active Yellow LED ON Green LED OFF OU...

Page 5: ...adjust output OUT2 press button 2 for 7 12s until the yellow and green LED flash alternately at 3Hz 3 Release the teach button to complete the teach event The current object distance has been taught...

Page 6: ...adapter position Teach GND The current state of output OUT2 is frozen during the teach event 3 The yellow LED flashes at 3Hz and is then ON The current object distance has been taught as the new swit...

Page 7: ...ughbeam sensor requires 2 sensors which are electrically connected through one line Switching outputs OUT1 OUT2 Switching point 1 2 The switching points can be directly entered as distance value in mm...

Page 8: ...HTU430B X3 LT4 M12 03 2019 05 8 HTU430B...