Starting up the device
Leuze electronic
DDLS 508
41
The LED of the newly selected operating mode flashes.
Activate the newly selected operating mode.
• Press the operating mode selector switch [MODE] for approx. two seconds until the LED of the newly
selected operating mode illuminates continuously.
• Release the operating mode selector switch [MODE] to activate the newly selected operating mode.
The previously activated operating mode is deactivated.
The LED of the newly selected operating mode illuminates continuously.
6.2
Fine adjustment
6.2.1 General procedure
Fine adjustment of the data transmission must be carried out after installation.
Prerequisites:
• The devices are mounted mutually opposing one another, are electrically connected and are roughly
aligned (see chapter 4 "Mounting").
• The devices are opposite one another at a close distance (> 1 m). The SIGNAL QUALITY indicator
shows at least one or two green LEDs on both devices.
If, while selecting a new operating mode, the operating mode selector switch [MODE] is not
pressed for a longer period of time (> 10 s), the previously activated operating mode remains ac
-
tive.
NOTICE
Cover reflectors of laser measurement systems during fine adjustment!
Cover the reflectors of a laser measurement system that is mounted next to the optical data transcei
-
ver during fine adjustment.