DeviceNet / CANopen
Leuze electronic
DDLS 200
39
TNT
35/7-2
4
V
9.2
DeviceNet/CANopen electrical connection - M12 connectors
The electrical connection of DeviceNet/CANopen is performed using M12 connectors.
Figure 9.5: Location and designation of the M12 DeviceNet/CANopen connections
Figure 9.6: Assignment M12 connector BUS IN
BUS IN (5-pin M12 connector, A-coded)
Pin
Name
Comment
1
Drain
Shield
2
V+
Positive supply bus transceiver
(switch S2 = bus)
3
V-
Negative supply bus transceiver
(switch S2 = bus)
4
CAN_H Bus signal High
5
CAN_L Bus signal Low
Thread
FE
Functional earth (housing)
BUS OUT
DeviceNet/CANopen:
M12 socket, A-coded
BUS IN
DeviceNet/CANopen:
M12 connector, A-coded
All M12 device models: PWR IN
M12 connector, A-coded
BUS IN
CAN_H
V+
3
2
1
4
V-
Drain
CAN_L
M12 connector
(A-coded)
DDLS200_E.book Seite 39 Mittwoch, 19. Februar 2020 12:22 12