Mounting and installation
Leuze electronic
BPS 301i
36
BCB mounting in horizontal curves
For horizontal curves, maintain a minimum bending radius of 300 mm (see figure 6.4).
1
BPS
2
Reading distance
3
Radius of the bar code tape, R
min
= 300 mm
Figure 6.4: Mounting the bar code tape for use in horizontal curves
BCB mounting in vertical curves
NOTICE
Limited absolute measurement accuracy and reproducibility!
BCB mounting in curves decreases the absolute measurement accuracy of the BPS, since the dis
-
tance between two bar codes is no longer exactly 40 mm or 30 mm.
NOTICE
Limited absolute measurement accuracy and reproducibility!
BCB mounting in curves decreases the absolute measurement accuracy of the BPS, since the dis
-
tance between two bar codes is no longer exactly 40 mm or 30 mm.
In areas where the BCB is fanned out around curves, limitations of the reproducibility must be
expected.
1
2
3