Display and control panel
84
BCL 504
i
Leuze electronic
Decoder table
In the
Decoder table
submenu, 4 different code type definitions can be stored. Barcodes
that have been read can only be decoded if they correspond to one of the definitions stored
here.
Table 8.2:
Decoder table submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Max. no. of
labels
Value between 0 and 64
The value set here specifies the maxi-
mum number of labels that should be
detected for each reading gate.
1
Decoder 1
Symbology
(Code type)
No code
Code 2 of 5 interleaved
Code 39
Code 32
Code UPC
Code EAN
Code 128
EAN Addendum
Codabar
Code 93
RSS 14
RSS Limited
RSS Expanded
If No code is configured, the current
and all subsequent decoders are
deactivated.
Code 2/5i
Number of digits
Interval mode
OFF/ON
With the ON setting, the values in dig-
its 1 and 2 define a range of character
numbers that are to be read.
OFF
Digits 1
0 to 64 characters
First decodable number of characters
or lower range limit.
10
Digits 2
0 to 64 characters
Second decodable number of charac-
ters or upper range limit.
0
Digits 3
0 to 64 characters
Third decodable number of charac-
ters.
0
Digits 4
0 to 64 characters
Fourth decodable number of charac-
ters.
0
Digits 5
0 to 64 characters
Fifth decodable number of characters.
0
Reading reliability
Value from 2 to 100
Number or scans required to reliably
detect a label.
4