Commissioning and configuration
140
BCL 504
i
Leuze electronic
10.10 Identifier
The following modules can be used to specify the segmentation process to be used when
extracting identifiers from the barcode data.
When a module is configured, the associated segmentation process is activated. If none of
the modules is configured, no segmentation takes place.
Therefore, the modules can only be used one at a time and not simultaneously.
Notice!
When using one of the following modules, multiple results may occur within a reading gate.
If there are multiple results, acknowledge mode must be used (cf. "Module 10 – Activations"
on page 119, "Mode" parameter and the additional notices); data may otherwise be lost!
10.10.1 Module 52 – Segmentation according to the EAN process
Description
The module activates the segmentation according to the EAN process. The parameters
specify the identifiers to searched for and the output mode.
Parameters
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Identifier list
Identifier 1
The identifier string is used for the iden-
tifier list and the filtering according to
the segmentation.
0
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
‘*‘
-
Identifier 2
See identifier 1.
5
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 3
See identifier 1.
10
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 4
See identifier 1.
15
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 5
See identifier 1.
20
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier output
Output with
identifier
If this switch is not set, the output of the
identifiers is suppressed. In this case,
only the data values belonging to the
identifiers are displayed.
25.0
Bit
0: Output of
the identifi-
ers is sup-
pressed.
1: Identifiers
are output.
1
-
Output delim-
iter
This delimiter, if not equal to 0, is
inserted between the identifier and the
associated data value in the output.
26
UNSIGNED8
0 … 127
0
-
Table 10.34:
Parameters for module 52