Commissioning and configuration
Leuze electronic
BCL 504
i
119
TNT 35/7-24V
10.7
Control modules
10.7.1
Module 10 – Activations
Description
The module defines the control signals for the reading operation of the barcode reader. It is
possible to select between standard reading operation and handshake operation.
In handshake operation, the controller must acknowledge the data reception via the ACK bit
before the new data is written into the input area.
After acknowledging the last decoding result, the input data is reset (filled with zeros).
Parameters
Parameter length
1 byte
Input data
None
Output data
Output data length
1 byte consistent
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Mode
The parameter defines the mode
in which the activation module is
operated.
0
UNSIGNED8
0: Without ACK
1)
1: With ACK
2)
1)
corresponds to BCL34 module 18
2)
corresponds to BCL34 module 19
0
-
Table 10.10:
Parameters for module 10
Output data
Description
Addr.
Data type
Value range
Init
value
Unit
Reading gate
Signal for activating the
reading gate
0.0
Bit
1 -> 0: Reading gate off
0 -> 1: Reading gate
active
0
-
Free
0.1
Bit
0
-
Free
0.2
Bit
0
-
Free
0.3
Bit
0
-
Data acknowl-
edgement
This control bit signals that
the transmitted data have
been processed by the
master.
Only relevant in handshake
mode (with ACK).
0.4
Bit
0 -> 1: Data has been
processed by the
master
1 -> 0: Data has been
processed by the
master
0
-
Data reset
Deletes decoding results
that may have been stored
and resets the input data of
all modules.
0.5
Bit
0 -> 1: Data reset
0
-
Free
0.6
Bit
Free
0.7
Bit
Table 10.11:
Output data for module 10