Commi
ss
ionin
g
and confi
g
uration
106
BCL
3
5
8
i
Le
u
ze electronic
Output assembly instance 122
In
s
t
a
nce 122,
a
ttri
bu
te
3
O
u
tp
u
t
ass
em
b
ly, length min. 1
b
yte
m
a
x. 261
b
yte
s
The n
u
m
b
er of d
a
t
a
s
t
a
rting
a
t
b
yte 6 i
s
defined in the control while config
u
ring the BCL
3
5
8
i
.
Thi
s
m
a
ke
s
it po
ss
i
b
le to
us
e the
ass
em
b
ly with
a
ny length.
Notice!
The use of the assembly is illustrated with examples at the end of this chapter.
Notice!
Formula for calculating the assembly length:
Length of the assembly = 6 + length of the entry data.
For entry data with length 10, the assembly must be configured with a length of 6 + 10 = 16.
Inst.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
122
0
Fragment number (see chapter 10.7.6 "Class 108 - Entry data")
1
Remaining fragments (see chapter 10.7.6 "Class 108 - Entry data")
2
Fragment size (see chapter 10.7.6 "Class 108 - Entry data")
3
Reserved
New
entry
(toggle bit)
New data
4
Entry data length (low byte)
5
Entry data length (high byte)
6
Data byte 0
7
Data byte 1
…
…
260
Data byte 254