Commi
ss
ionin
g
and confi
g
uration
Le
u
ze electronic
BCL
3
0
8
i
99
TNT
35/7-2
4
V
10.4.3
Control of the
s
witchin
g
output
s
By
us
ing the
s
witching inp
u
t
s
/o
u
tp
u
t
s
of the BCL
3
0
8
i
, extern
a
l event-controlled f
u
nction
s
c
a
n
b
e implemented witho
u
t
ass
i
s
t
a
nce from the
su
perior proce
ss
control. For thi
s
p
u
rpo
s
e,
the re
s
pective connection
a
t the
S
W IN/OUT
a
nd POWER interf
a
ce
s
m
us
t
b
e config
u
red
as
a
s
witching o
u
tp
u
t.
A
s
witching o
u
tp
u
t c
a
n
b
e
a
ctiv
a
ted:
•
a
t the
s
t
a
rt/end of the re
a
ding g
a
te
• depending on the re
a
d re
su
lt:
•
reference code comp
a
ri
s
on po
s
itive/neg
a
tive
•
re
a
d re
su
lt v
a
lid/inv
a
lid
• depending on the
s
t
a
te of the device:
•
re
a
dy/not re
a
dy
•
d
a
t
a
tr
a
n
s
mi
ss
ion
a
ctive/not
a
ctive
•
a
ctive/
s
t
a
nd
b
y
•
error/no error
• etc.
As described in chapter 7 of the manual, connect the required switching outputs.
Configure the connected switching outputs according to your requirements. To do this,
first set the I/O mode to Output and then configure the switching behavior:
• Vi
a
we
b
Config:
Configuration -> Device -> Switching inputs/outputs