Online commands
Leuze electronic
BCL 608i
64
Acknowledgment
positive
PT<BCC type><PS type><Status><Start>
<Parameter value - address><Parameter value - 1>…
[;<Address><Parameter value - address>][<BCC>]
<BCC type>
Check-digit function during transmission,
unit [dimensionless]
0
Not used
3
BCC mode 3
<PS type>
Memory from which the values are to be read,
unit [dimensionless]
0
Parameter values stored in the flash memory
2
Default values
3
Operating values in RAM
<Status>
Mode of parameter processing,
unit [dimensionless]
0
No further parameters
1
Additional parameters follow
<Start>
Relative address of the data within the data set
aaaa Four-digit,
unit [dimensionless]
<P.value A.> Parameter value of the parameter stored at this address; the
parameter set data 'bb' is converted from HEX format to a 2-
byte ASCII-format for transfer.
<BCC>
Check sum calculated as specified under BCC type
Acknowledgment
negative
PS=<aa>
Parameter reply:
<aa>
Status acknowledgment,
unit [dimensionless]
01
Syntax error
02
Impermissible command length
03
Impermissible value for checksum type
04
Invalid check sum received
05
Impermissible number of data requested
06
Requested data does not (any longer) fit in the transmission
buffer
07
Impermissible address value
08
Read access after end of data set
09
Impermissible QPF data set type
Command
PR