![Leuze electronic ARH Series Manual Download Page 2](http://html1.mh-extra.com/html/leuze-electronic/arh-series/arh-series_manual_1883978002.webp)
2016/02
Dimensioned drawings
ARH 96
ARH 96
ARH 46
ARH 46
Specifications
Order guide
Electrical data
Voltage supply
2 commercially available AAA batteries 2x1.5V replaceable
Ready to operate
approx. 8 hours in permanent operation
Switching on/off
by pressing the flip switch
Visual range
approx. 50m depending on ambient light
Light wavelength
650 … 670nm (visible red light)
Laser class
2 in accordance with EN 60825-1:2007
Mechanical data
Housing aluminium
Environmental data
Ambient temp. (operation/storage) -20°C … +55°C/-30°C … +70°C
Protection class
IP 45
Standards applied
EN 60825-1, 21 CFR 1040.10
Designation
Part No.
Laser-box
ARH 10
50080537
Complete for 46B series
ARH 46
50040739
Complete for 46C series
ARH 46C
50129659
Complete for 49C series
ARH 49C
50129660
Complete for 96 series
ARH 96
50080502
Remarks
Mounting for
ARH 46/46C
The bracket is placed on top
of the housing (46B series/
46C series).
Mounting for
ARH 96/49C
The cover of the sensor
(96 series/49C series) has to
be open.
The ARH 96 is fastened to
the thread hole of the cover
by using the knurl screw.
Operation
After switching on through
the flip switch, a laser beam
projects a visible red light
spot which simulates the
optical axis of the transmitter
respectively the receiver.
Now, the transmitter can be
adjusted in such a way, that
the light spot hits, depending
on the application:
receiver/transmitter on the
opposing side (through-
beam photoelectric
sensors)
the reflector in the middle
(retro-reflective photo-
electric sensors)
the object to be scanned
(diffuse reflection light
scanner)
Battery change
To change the AAA cells, the
two screws M2.5 on the bot-
tom and the cover have to be
removed. Change the AAA
cells acc. to the figure, mount
the cover and fasten the
screws.
Intended use
The laser alignment aids are
aids for the optical alignment
of optical electronic sensors.
Operate in accordance with
intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.
ARH