Mounting
Leuze electronic
AMS 200
3
1
TNT
3
5/7-2
4
V
7
Mounting
7.1
Mounting the AMS 200…
Figure 7.1: Mounting the device
The AMS 200… and the corresponding reflector should be mounted on two opposing,
plane-parallel, flat
walls or plant components. For error-free position measurement there
must be
unobstructed line of sight between the AMS 200… and the reflector
.
Use the M5 screws to mount the laser measurement system.
Secure the screws with a
toothed lock washer
to protect against loosening caused by vibrations.
The laser light spot has to be aligned so that it always hits the centre of the opposing
reflector, both at close range as well as at the maximum measurement distance. Use
the
two M5 hexagon socket screws to align the device
("
A
" in figure 7.1). When aligning
please ensure that the knurled nut and the M5 lock nut ("
B
" in figure 7.1) are opened wide.
Attention
!
To prevent the laser measurement system from becoming misaligned during continuous op-
eration, then
hand-tighten the knurled nut
and
securely lock into place with the M5 nut
("
B
" in figure 7.1). Knurled nut and M5 nut must not be tightened until
after aligning
.
Attention
!
The device must not be opened. Failure to comply will render the guarantee void. Warranted
features cannot be guaranteed after the device has been opened.
A
M5 Allen screws for
aligning
B
Knurled nut and
M5 nut for securing
C
Optical axis
D
Must not be
adjusted
!