Display and control panel AMS 301i
Leuze electronic
AMS 301
i
44
TNT
35/7-2
4
V
Other submenu
8.3.3
Language selection menu
There are 5 display languages available:
• German
• English
• Spanish
• French
• Italian
The AMS 301
i
is delivered from the factory with the display preset to English.
To change the language, no password needs to be entered nor must password enabling
be activated. The display language is a passive operational control and is, thus, not a
function parameter, per se.
Table 8.5:
Other submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Heating control
Standard (10° C … 15° C)/Extended (30° C … 35° )
Defines a switch-on/switch-off range for the heating control.
The extended switch-on/switch-off range for heating may provide relief
in the event of condensation problems.
There is no guarantee that no condensation will occur on the optics in the
extended switch-on/switch-off range due to the limited heating capacity.
This parameter is available as standard, but functions only for devices
with integrated heating (AMS 301
i
…
H
).
Standard
Display
illumination
10 minutes/ON
Display illumination is switched off after 10 minutes or, if the parameter
is set to "ON", illumination is always on.
10 min.
Display contrast
Weak/Medium/Strong
The display contrast may change at extreme temperature values. The
contrast can subsequently be adapted using the three levels.
Medium
Service RS232
Baud rate
57.6 kbit/s / 115.2 kbit/s
The service interface is only available to Leuze internally.
115.2 kbit/s
Format
8,e,1 / 8,n,1
The service interface is only available to Leuze internally.
8,n,1
Language selection
o Deutsch
English
o Español
o Français
o Italiano