Installation and mounting
Leuze electronic
AMS 301
i
16
TNT
35/7-2
4
V
If you have any questions concerning your shipment, please contact your supplier or your
local Leuze electronic sales office.
ª
Observe the applicable local regulations when disposing of the packaging materials.
5.2
Mounting the AMS 301
i
Figure 5.2:
Mounting the device
The AMS 301
i
and the corresponding reflector are mounted on two mutually opposing,
plane-parallel, flat walls or system parts. For error-free position measurement, there must
be an unobstructed line-of-sight connection between the AMS 301
i
and the reflector.
Use M 5 screws to fasten the laser measurement system. Secure the screws with a toothed
lock washer to protect against loosening caused by vibrations.
A
M 5 screw for
alignment
B
Knurled nut and
WAF 4 nut for
securing
C
Optical axis
A
B
A
C