6
The Optional Remote 3rd Hole Slide - LESCO No. 030571
Mounting Instructions
1.
Mount the dual lever bracket (Ref. 1) to the right
handle using one machine screw (Ref. 2), one flat
washer (Ref. 3) and one hex nut (Ref. 4) as shown
below.
2.
Mount the dual remote lever (Ref. 5) to the dual
lever bracket (Ref. 1) using one machine screw
(Ref. 6), two nylon flat washers (Ref. 7) and one
hex nut (Ref. 4) as shown below.
3.
Slide the control cable (Ref. 8) through the hole in
the dual remote lever and the cable housing into
the fork of the dual lever bracket and pinch the
forks around the cable groove.
4.
With the dual remote lever pushed all the way
forward attach the other end of the control cable to
the hole in the 3rd hole slide. Push the slide fully
closed and mount the cable housing to the shut off
plate using the cable clamp (Ref. 9), two machine
screws (Ref. 10), two lock washers (Ref. 11) and
two hex nuts (Ref. 12) as shown below.
5.
Work the dual remote lever back and forth to be
sure that you are getting the full open and full
closed positions of the 3rd hole slide. If not, loosen
the cable clamp and adjust the cable.
Parts List
Ref.
No.
Part No. Description
Qty.
1
030418
Bracket, Dual Lever
1
2
060047
Machine Screw
1
3
060033
Flat Washer 1/4
1
4
060036
Hex Nut, 1/4-20 Nylock
2
5
030416
Lever, Dual Remote
1
6
060057
Machine Screw
1
7
018628
Flat Washer, 1/4 Nylon
2
8
030450
Control Cable
1
9
020511
Cable Clamp
1
10
031686
Machine Screw
2
11
060083
Lock Washer #8
2
12
060056
Hex Nut, #8-32
2
Impeller Shaft Support
Bottom of Hopper