Leprecon ULD-360 User Manual Download Page 4

- 4 -

1) 

Introduction

The new ULD series dimmer is designed to be a capable and reliable solution for
temporary and portable dimming requirements.  With the menu-based interface, the
dimmer can be configured for different applications, including stand-alone use
without a controller.  Default values can be restored at any time, clearing the internal
memory back to the standard values.

Please take a few minutes to review the specifications and operating features of the
ULD-360 dimmer.

The ULD-360 dimmer is designed for use with conventional incandescent fixtures.
Transformer loads, such as low voltage devices using a step-down transformer, may
require an additional load to be connected to the same circuit to operate properly.
For operating florescent fixtures, see the section regarding Front Panel Controls.

2) Specifications

Power Connection

Unless otherwise indicated, your ULD-360 dimmer is designed for connection to
standard US power systems, 120 VAC 60 Hz.  Lamp connections must be 120 V
devices only.  Line voltages over 135 VAC will trigger the overvoltage protection
circuit and shut off the dimmer pack.

Ambient Temperature

The ULD-360 dimmer is designed for use in a cool, ventilated area.  Ambient
air temperature must be less than 40 degrees Celsius, or about 104 degrees
Fahrenheit.

Power Capacity

The ULD-360 DMX is unique in the market of small portable dimmers. A single
breaker is used on the pack instead of individual fuses per each channel. As a
result, the limits of the dimmer are 

pack

 limits, not channel limits. The following

guidelines should be followed:

ULD-360 DMX
Pack Limit: 15 Amps

ULD-360 DMX-HP
Pack Limit: 15 Amps per line cord, or 30 amps total

Summary of Contents for ULD-360

Page 1: ...2005 2008 All rights reserved Publication 21 1046 Rev A This document is the property of Leprecon LLC and is provided for service and instructional purposes only Possession does not imply or convey r...

Page 2: ...Temperature 4 Power Capacity 4 Control input 5 3 Optional Wireless DMX 6 3 Installation 8 Mounting 8 Power Connection 8 Load Connection 8 4 Turning on Power 8 5 Front Panel Controls 9 Resetting the U...

Page 3: ...3 Endplate Illustration ULD 360DMX HP Menu Enter Data In ULD Series Line A Line B Data Out ON I O OFF ON I O OFF d 0 0 DMX Out DMX In LED display Breaker A...

Page 4: ...ating florescent fixtures see the section regarding Front Panel Controls 2 Specifications Power Connection Unless otherwise indicated your ULD 360 dimmer is designed for connection to standard US powe...

Page 5: ...d and acceptable cable see the Appendix at the end of this manual For convenience DMX in and out connectors are provided on the ULD 360DMX This allows easy connection to additional dimmer packs The DM...

Page 6: ...al receiver card and power supply External antenna Switch and LED indicator for setting the communication link Background Information The W DMX system uses a 2 4 ghz radio signal to transmit DMX data...

Page 7: ...down for four seconds The LED will turn off indicating that the link has been broken To establish a link to a specific transmitter 1 Unlink the dimmer by pressing and holding the switch as described a...

Page 8: ...protected by a properly sized circuit breaker If you have any questions about the suitability of the power circuit that you intend to use with the LD360 dimmer consult with a qualified electrician Lo...

Page 9: ...y depressing and holding the ENTER switch while turning on the first breaker Address Menu When the dimmer is first turned on the display shows the starting channel address of the ULD 360 This is the D...

Page 10: ...control channel 2 and so on for all of the circuits in the pack If you have multiple ULD dimmers generally the first dimmer will be set to start address 001 Assuming that each dimmer has six circuits...

Page 11: ...olon will blink to indicate new data has been entered Press the ENTER key saves the change and advance to the next channel The ULD 360 returns to the Address Menu automatically after 4 seconds if no k...

Page 12: ...ing from Channel 1 to Channel 6 then automatically cycle back to channel 1 This automatic cycling is indicated by the flashing colon The Status Mode first displays the current input state of the dimme...

Page 13: ...o and manual cycle modes In manual mode the menu steps through its displays when the UP or DOWN keys are pressed The colon is steady in manual mode If a channel has been set to a fixed level in the Ch...

Page 14: ...or conditions The ULD 360 will protect itself if the line voltage or operating temperature exceeds safe limits In these cases the dimmer will turn off all channels and display an error message on the...

Page 15: ...eck power wiring Overload breaker trips check wattage of loads If a problem is verified in the dimmer pack contact your Leprecon dealer for service Because of the high voltages present inside of the d...

Page 16: ...ard specifies the use of 5 pin XLR connectors DMX 512 currently uses 3 pins of the 5 pin connector Pins 4 and 5 are reserved for future use Some manufacturers are using these pins for communications b...