[Notice] When the relay is triggered because of Event 2~5, the relay contact alarm, will update the status
every 30 seconds. If there is no event happening for 30 seconds, the relay contact alarm will be turn off. If
the user disables the failed PoE port by removing the cable or Dip Switch manually, the relay will be
recovered immediately.
Ethernet Ports
RJ-45 Ports (Auto MDI/MDIX)
The RJ-45 ports are auto-sensing for 10Base-T, 100Base-TX or 1000Base-T devices
connections. Auto MDI/MDIX means that the unit can connect to another one or
workstation without changing the straight-through or crossover cabling. See the
figures as below for straight-through and crossover cabling schematics.
10/100BASE-T(X) RJ-45 Pin Assignments
(Table 2.3)
Crossover Cable
Straight Through Cable
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
1 / RX+
3 / TX+
1 / RX+
1 / TX+
2 / RX-
6 / TX-
2 / RX-
2 / TX-
3 / TX+
1 / RX+
3 / TX+
3 / RX+
6 / TX-
2 / RX-
6 / TX-
6 / RX-
Table 2.3
1000BASE-T RJ-45 Pin Assignments
(Table 2.4)
Crossover Cable
Straight Through Cable
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
1 / TP0+
3 / TP1+
1 / TP0+
1 / TP1+
2 / TP0-
6 / TP1-
2 / TP0-
2 / TP1-
3 / TP1+
1 / TP0+
3 / TP1+
3 / TP0+
4 / TP2+
7 / TP3+
4 / TP2+
4 / TP3+
5 / TP2-
8 / TP3-
5 / TP2-
5 / TP3-
6 / TP1-
2 / TP0-
6 / TP1-
6 / TP0-
7 / TP3+
4 / TP2+
7 / TP3+
7 / TP2+
8 / TP3-
5 / TP2-
8 / TP3-
8 / TP2-
Table 2.4
Note:
“+” and “
-
” signs represent the polarity of the wires that make up each wire pair.