MOUNTING INSTALLATION

 

DIN-Rail Mounting 

The DIN-Rail is pre-installed on the injector from the factory. If the DIN-Rail is not on the unit, please see 
Figure 3.1 to learn how to install the DIN-Rail on it. 
 

 

 

Figure 3.1: The Rear Side of the Injector and Wall Mounting Bracket

 

 

 

 

Summary of Contents for GINJ-0201-EBT-T

Page 1: ...GINJ 0201 EBT T...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...tions FCC Ces limites sont con ues pour fournir une protection raisonnable contre toutes interf rences nuisibles dans un milieu r sidentiel Cet quipement g n re utilise et peut mettre de l nergie de f...

Page 4: ...t Panel 4 Top View 4 LED Indicators 5 DIP Switch Setting 6 Relay Contact Alarm Warning 6 Ethernet Ports 7 Cabling 8 Wiring the Power Inputs 8 Wiring the Fault Alarm Contact 9 Grounding Note 9 MOUNTING...

Page 5: ...ies also works perfectly in polarized temperatures from 40 75 and undoubtedly becomes your best option in a harsh environment GINJ 0201 EBT Series with a fan less design besides extending surely apply...

Page 6: ...if de protection sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du converti...

Page 7: ...HARDWARE DESCRIPTION Physical Dimensions Figure 2 1 below shows the physical dimensions of GINJ 0201 EBT Series W x H x D is 30mm x 95mm x 75mm Figure 2 1 Physical Dimensions...

Page 8: ...ow shows the top panel of the GINJ 0201 EBT Series Industrial Gigabit BT PoE Injector that is equipped with one 2 pin terminal block for relay contact alarm and 4 pin terminal block connectors for dua...

Page 9: ...n The PoE output port is supplying power to the powered device over 4 pairs Amber Flashing The PoE output port is supplying power to the powered device over 2 pairs after the Dual PD Check event happe...

Page 10: ...t if an invalid detection signature is discovered on either channel the port will not perform classification or grant power on requests Note 1 When Dual PD Check is disabled in Standard PoE Mode and o...

Page 11: ...r crossover cabling See the figures as below for straight through and crossover cabling schematics 10 100BASE T X RJ 45 Pin Assignments Table 2 3 Crossover Cable Straight Through Cable Pin Number Sign...

Page 12: ...tive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 4 Figure 2 4 Power Terminal Block Step 2 Tighten the wire clamp screws to...

Page 13: ...ct is shown below in Figure 2 6 Figure 2 6 fault alarm contact Grounding Note Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connecti...

Page 14: ...ting The DIN Rail is pre installed on the injector from the factory If the DIN Rail is not on the unit please see Figure 3 1 to learn how to install the DIN Rail on it Figure 3 1 The Rear Side of the...

Page 15: ...IN Rail bracket is installed on the rear side of the injector insert the top of the DIN Rail on to the track as shown below in Figure 3 2 Figure 3 2 Insert the Injector on the DIN Rail Step 4 Lightly...

Page 16: ...al Ethernet injector Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet injector Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the indu...

Page 17: ...ial injector on a DIN Rail or wall please refer to the Mounting Installation section Step 4 Power on the industrial injector and then the power LED light will turn on If you need help on how to wire p...

Page 18: ...t me int grant l quipement est de la responsabilit de l assembleur du syst me Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agit...

Page 19: ...turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power connections power losses or surges at the power outlet Please contact Leonton for techni...