13 

HARDWARE INSTALLATION

 

Installation Steps 

This section will explain how to install EG5-1600-M12XB-110-67 series.

 

Installation Steps 

Step 1.

 

Unpack the industrial Ethernet switch from the original packing box.

 

Step 2.

 

To hang the industrial Ethernet switch on a wall, please refer to the Mounting Installation section.

 

Step 3.

 

Power on the industrial Ethernet switch and then the power LED light will turn on.

 

 

If you need help on how to wire power, please refer to the 

Power Inputs

 section.

 

 

Please refer to the 

LED Indicators

 section for LED light indication.

 

Step 4.

 

Prepare the M12 cable for Ethernet connection.

 

Step 5.

 

Insert  one  side  of  the  M12 

cable  into  switch’s  Ethernet  port  and  on  the  other  side  into  the 

networking device’s Ethernet port

The Ethernet port’s (

L/A) LED on the industrial Ethernet switch 

will turn on when the cable is connected to the networking device.

 

 

Please refer to the 

LED Indicators

 section for LED light indication.

 

Step 6.

 

When all connections are set and the LED lights all show normal, the installation is complete.

 

 

 

Summary of Contents for EG5-1600-M12XB-110-67

Page 1: ...EG5 1600 M12XB 110 67 EG5 1600 M12XB 110 T67...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...tions FCC Ces limites sont con ues pour fournir une protection raisonnable contre toutes interf rences nuisibles dans un milieu r sidentiel Cet quipement g n re utilise et peut mettre de l nergie de f...

Page 4: ...l Dimensions 3 Front Panel 4 LED Indicators 5 Ethernet Ports 6 USB Port 7 Console Port 7 Power Inputs 8 Relay Contact and Digital Input 9 Grounding Note 11 Bypass Function 11 Reset to Default 11 MOUNT...

Page 5: ...of 40 C 70 C this series is designed to meet any needs for industrial automation application and harsh environments Key Features Interface Performance Copper port support auto MDI MDI X function Embed...

Page 6: ...de protection sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du convertiss...

Page 7: ...3 HARDWARE DESCRIPTION Physical Dimensions Figure 2 1 below shows the physical dimensions of EG5 1600 M12XB 110 67 series W x H x D is 295mm x 160mm x 101 3mm Figure 2 1 Physical Dimensions...

Page 8: ...2 2 On the front panel it provides 16 M12 connectors in a polka dot pattern to ensure easier plugging and safer operation The LED indicates various status by different colors and shapes of the light...

Page 9: ...ent happened after the last reset or reboot Red On 1 System booting 2 Event happened by software setting Red Flashing Firmware Upgrade Master Green On ERPS Owner Mode Ring Master is ready Off ERPS Own...

Page 10: ...BI_DD 6 BI_DD 7 BI_DC 8 BI_DC Table 2 2 Note and signs represent the polarity of the wires that make up each wire pair Connection of Cables Use the twisted pair cable category 5e or the above cabling...

Page 11: ...on backup restore M12 connector M12 4 Pin A Coded female Connector Pinouts Function 1 DN 2 VBUS 3 GND 4 DP Console Port It is a M12 5 Pin A Coded female connector Baud rate 115 200bps 8 N 1 M12 connec...

Page 12: ...assignment M12 5 Pin K Coded Male Connector Pinouts Function 1 V1 2 V1 3 V2 4 V2 5 GND Table 2 3 Connection of Cables Minimum Wire Gauge 18AWG Please follow the below steps to insert the power wire St...

Page 13: ...Power 1 or Power 2 was inactive 3 If any one of all PoE ports exceeds 30Watts for PoE models 4 Event happened by software setting Relay is closed under the conditions below 1 No event after reboot 2 N...

Page 14: ...tage the DI function will be triggered Table 2 5 is shown a detail specification of the digital input Specification Description Level 0 Low 30 8VDC Will trigger DI function active trigger states Level...

Page 15: ...es loses power Ethernet ports P8 and P16 will bypass the power lost Ethernet switch to prevent the network from disconnecting Take Figure 2 5 for example if Switch B has power failure the bypass funct...

Page 16: ...nded use the M5 screws Step 2 Based on the Figure 3 2 Physical Dimensions which is shown the positions of 4 screw holes on the left and right side of the switch to make 4 screw holes on a wall accordi...

Page 17: ...elp on how to wire power please refer to the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 4 Prepare the M12 cable for Ethernet connection Step 5 Insert...

Page 18: ...st me int grant l quipement est de la responsabilit de l assembleur du syst me Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agi...

Page 19: ...which help to identity if any problems exist Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user...

Reviews: