Ethernet Ports 

RJ-45 Ports

 

(Auto MDI/MDIX)

 

The  RJ-45  ports  are  auto-sensing  for  10Base-T,  100Base-TX  or 
1000Base-T  devices  connections.  Auto  MDI/MDIX  means  that  the 
switch  can  connect  to  another  switch  or  workstation  without 
changing the straight-through or crossover cabling. See the figures 
as below for straight-through and crossover cabling schematics. 

 

10/100BASE-T(X) RJ-45 Pin Assignments

 (Table 2.2) 

Crossover Cable 

Straight Through Cable 

Pin Number / Signal 

Pin Number / Signal 

Pin Number / Signal 

Pin Number / Signal 

1 / RX+ 

3 / TX+ 

1 / RX+ 

1 / TX+ 

2 / RX- 

6 / TX- 

2 / RX- 

2 / TX- 

3 / TX+ 

1 / RX+ 

3 / TX+ 

3 / RX+ 

6 / TX- 

2 / RX- 

6 / TX- 

6 / RX- 

Table 2.2 

 
1000BASE-T RJ-45 Pin Assignments

 (Table 2.3) 

Crossover Cable 

Straight Through Cable 

Pin Number / Signal 

Pin Number / Signal 

Pin Number / Signal 

Pin Number / Signal 

1 / TP0+ 

3 / TP1+ 

1 / TP0+ 

1 / TP1+ 

2 / TP0- 

6 / TP1- 

2 / TP0- 

2 / TP1- 

3 / TP1+ 

1 / TP0+ 

3 / TP1+ 

3 / TP0+ 

4 / TP2+ 

7 / TP3+ 

4 / TP2+ 

4 / TP3+ 

5 / TP2- 

8 / TP3- 

5 / TP2- 

5 / TP3- 

6 / TP1- 

2 / TP0- 

6 / TP1- 

6 / TP0- 

7 / TP3+ 

4 / TP2+ 

7 / TP3+ 

7 / TP2+ 

8 / TP3- 

5 / TP2- 

8 / TP3- 

8 / TP2- 

Table 2.3

 

 

Note: 

“+” and “-” signs represent the polarity of the wires that make up each wire pair.

 

 

Summary of Contents for EG2-1002-SFP Series

Page 1: ...LEONTON EG2 1002 SFP Series EG2 1002 SFP EG2 1002 SFP T User Manual...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...equipment D claration FCC Cet quipement a t test et reconnu conforme aux limites de la classe A pour les quipements num riques conform ment la section 15 des R glementations FCC Ces limites sont con u...

Page 4: ...equired to take adequate measures CE Mark AVERTISSEMENT Ceci est un produit de classe A Dans un environnement domestique ce produit peut tre utilis en pr sence d interf rences radio This document is t...

Page 5: ...ption 3 Physical Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 6 Cabling 7 Wiring the Power Inputs 9 Wiring the Fault Alarm Contact 11 Mounting Installation 12 DIN Rail Mountin...

Page 6: ...10 C 65 C and another with a wide operating temperature of 40 C 75 C this series is designed to meet any needs for industrial automation application and harsh environments Key Features Interface Perfo...

Page 7: ...witch s hardware specs ports cabling information and wiring installation will be described within this user manual ATTETNION Si la tension CC est fournie par un circuit externe veuillez utiliser un di...

Page 8: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of EG2 1002 SFP series W x H x D is 46mm x 142mm x 99mm Figure 2 1 EG2 1002 SFP Series Physical Dimensions...

Page 9: ...shown below in Figure 2 2 Figure 2 2 The Front Panel of EG2 1002 SFP Series Top View Figure 2 3 below shows the top panel of the EG2 1002 SFP series switch that is equipped with one 6 pin removal ter...

Page 10: ...ive P2 Green On Power input 2 is active Off Power input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both functional SFP Port LINK ACT Green On Connected to th...

Page 11: ...raight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 1000BASE T RJ 45...

Page 12: ...t optical transceiver used in optical communications for both telecommunication and data communication applications To connect the transceiver and LC cable please follow below steps Step 1 Insert the...

Page 13: ...ure 2 11 Figure 2 11 LC Connector to the Transceiver To remove the LC connector from the transceiver please follow the steps shown below Step 1 Press the upper side of the LC connector from the transc...

Page 14: ...the Power Inputs Please follow the below steps to insert the power wire Step 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as sh...

Page 15: ...10 Figure 2 15 Power Terminal Block Note Only use copper conductors 60 75 C tighten to 5 lbs The wire gauge for the terminal block should range between 18 20 AWG...

Page 16: ...luding power failure or port link failure managed industrial switch only and form a normally open circuit An application example for the fault alarm contact is shown below in Figure 2 16 Figure 2 16 W...

Page 17: ...ure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear si...

Page 18: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Eth...

Page 19: ...strial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the indu...

Page 20: ...o the Mounting Installation section Step 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power...

Page 21: ...assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indicat...

Reviews: