ALM
When the battery is at fault, "ALM" light is red.
RUN
During charging, the "RUN" light will be flashing.
"RUN" and "ALM" can display the battery status, as shown in table 2-2.
Table2-2
The explanation of “RUN” and “ALM”
Function
Mark
Color
Flashing frequency
Indication
Running
RUN
Green
No light
Not working
Slow Flash(about 3 secs)
Standby state
Fast flash
Working state
Alarm
ALM
Red
No light
Normal
stable lighting
Alarm
ADD
In parallel, band switch using four dip switch to address set cell system. The
explanation of its dial switch as shown in table 2-3.
Table2-3
Band switch address code
Address Code
ADD PACK
Definition
Explanation
1
2
3
4
5
6
OFF
OFF
OFF
OFF
/
/
0
Use Alone
ON
OFF
OFF
OFF
1
PACK
Use As MasterPack,
Can apply Telecom
RS-232
OFF
ON
OFF
OFF
2
PACK1
Use as SlavePack1
ON
ON
OFF
OFF
3
PACK2
Use as SlavePack2
OFF
OFF
ON
OFF
4
PACK3
Use as SlavePack3
ON
OFF
ON
OFF
5
PACK4
Use as SlavePack4
OFF
ON
ON
OFF
6
PACK5
Use as SlavePack5
ON
ON
ON
OFF
7
PACK6
Use as SlavePack6
OFF
OFF
OFF
ON
8
PACK7
Use as SlavePack7