LEO APm37 Instruction Manual Download Page 12

Acquaer Ltd. 

 

 H-

4900, Fehérgyarmat, Szatmári út 11.

 

 

Troubleshooting 

 

Check the pump after power cut-off. 
 
 

Symptom 

Cause 

Corrective Action 

The  motor  cannot  be 
started 

Single-phase  power 
supply  (three-phase 
electric motor): 

a. 

poor  connection  of 
the power switch; 

b. 

fuse is burned out; 

c. 

loose power lead; 

phase failure of the cable. 

a. 

repair  switch  contact 
or replace the switch; 

b. 

replace the safety fuse; 

c. 

check  and  tighten 
the 

power 

connector; 

d. 

repair or replace cables. 

Capacitor is burned out. 

Replace with a same type 
capacitor  (send  to  the 
maintenance  point  for 
repair). 

The  rotating  shaft  and 
bearing are jammed. 

Replace  the  bearing 
(send 

to 

the 

maintenance  point  for 
repair). 

Impeller is jammed. 

Turn rotating shaft of the 
fan  blade  terminal  with 
screw  driver  to  let  it 
rotate flexibly or demount 
the  pump  body  to  clear 
sundries. 

Stator winding is damaged. 

Replace  winding  coils 
(send to the maintenance 
point for repair). 

 
 

The 

motor 

is 

in 

operation, but no water 
is discharged 

Incorrect direction of pump 
rotation. 

Invert 

two-phase 

wirings  of  the  motor 

(three-phase motor). 

The pump is not fully filled 
with water. 

Re-fill  the  pump  with 
water. 

The impeller is damaged. 

Replace the impeller (send 
to  the  maintenance  point 
for repair). 

Leakage  of  the  suction 
pipe. 

Check  sealing  of  various 
joints of the inlet pipelines. 

Water level is too low. 

Adjust installation height of 
the pump. 

Freeze 

caused 

by 

accumulated  water  in  the 
pipeline or the chamber. 

Start up the pump after ice 
is melted. 

 

Insufficient pressure 

Incorrect pump type. 

Select suitable pump. 

 

 

 

Summary of Contents for APm37

Page 1: ...Acquaer Ltd H 4900 Fehérgyarmat Szatmári út 11 PERIPHERIAL PUMP Instruction Manual APm37 APm75 ...

Page 2: ...ces as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available Applications It is applicable to household water supply equipment support small air conditioning system pipeline pressurization garden watering vegetable greenhouse watering fish breeding and poultry raising etc Transfer clean water and other n...

Page 3: ...er 0 25 2 2kW Max Suction 8m Insulation class IPX4 Protection class F Max ambient temperature 40 Max liquid temperature 60 Type APm37 APm75 Power 370 W 0 5 HP 750 W 1 0 HP Inlet outlet diameter 1 1 1 1 Qmax 2 4 m3 h 3 0 m3 h Hmax 35 m 70 m Max Suction 8 m 8 m Gross weight 5 5 kg 10 5 kg Package 283x158x171mm 335x190x210mm ...

Page 4: ...ure normal and safety operation of the electric pump read the manual carefully before use The electric pump should have reliable grounding to prevent short circuit for safety leakage protection switch should be equipped and be careful not to wet the power plug socket should be connected in damp proof area Do not touch the electric pump while working do not wash swim near working area or let livest...

Page 5: ...alves in both sides of the bump should be turned off first and then empty liquids in the pump and pipelines so as not to be scalded Do not transfer any inflammable explosive or gasified liquids that beyond the stipulation Ensure the pump will not be accidently turned on while installing and maintaining if not used for a long time cut off the power first and then turn off valves in inlet and outlet...

Page 6: ...ture POS Part POS Part 1 Pump body 10 Fan 2 Impeller 11 End plate 3 Mechanical seal 12 Cable holder 4 Support 13 Cord clip 5 Water proof gland 14 Capacitor 6 Bearing 15 Capacitor box 7 Rotor 16 Terminal board 8 Spring washer 17 Stator 9 Fan cover 18 Filling plug ...

Page 7: ...ards Install pipelines properly as stipulated in the manual and meanwhile conduct frost protection measures for the pipeline For the installation the inlet pipe should be as short as possible with the least turnings The pump should be installed in ventilated and dry environment It could be installed outside provided having proper covering to prevent rain and wind For pipeline use valves should be ...

Page 8: ...st in accordance with that of the water inlet to avoid too much water loss which will influence outlet performance 5 Pay attention to drop of water level while using the foot valve should not be above the water surface B1 6 In case the inlet pipe is longer than 10m or its lifting height exceeds 4m the pipe diameter should exceed diameter of water inlet of the pump 7 Ensure the pumped will not be a...

Page 9: ...ith power supply In case the working area of the electric pump is too far from the power supply power transmission lines should be of a heavier gauge otherwise the electric pump cannot work normally because the voltage drop is too dramatic A rubber extension cable shall be applied for the electric pump in case of outdoor use Check rotation of the motor three phase motor Check whether operation of ...

Page 10: ... acquire lower closing pressure o In case the pump is often enabled when the water tap is turned off sometimes it is turned on and sometimes it is turned off check whether pipeline and the bottom valve have leakages and pressure vessel pressure is normal eliminate timely if any o In case the pressure switch is alternately turned on and turned off frequent start after turning on the water tap incre...

Page 11: ...e Attention In case no water is discharged after being started for more than 5 minutes with water filled turn off the electric pump re fill water or check whether the inlet pipeline has leakages In case of any frost and ice damages please open the drain plug to empty water in the pump chamber When start up the pump again open the drain plug fill water and tighten it and then the pump is usable In ...

Page 12: ...ir Impeller is jammed Turn rotating shaft of the fan blade terminal with screw driver to let it rotate flexibly or demount the pump body to clear sundries Stator winding is damaged Replace winding coils sendtothe maintenance point for repair The motor is in operation but no water is discharged Incorrect direction of pump rotation Invert two phase wirings of the motor three phase motor The pump is ...

Page 13: ...lter screen or pump chamber is blocked by foreign materials Clean pipeline foot valve or pump chamber clear sundries Motor works intermittently or the stator winding is burned out The impeller is jammed or under overload operationfora longtime Clear sundries in the pump chamber operate the pump under the rated flow as much as possible Incorrect grounding broken cable or the electric pump is hit by...

Page 14: ... to material or manufacturing faults will be rectified exclusively by our contracted workshops the seller has the right to remedy a defect in your vicinity or by the manufacturer if the latter is closer Any claims going beyond the provision of a guarantee are ruled out Any transport damage should be reported not to us but to the shipper in question since otherwise any compensation claims the shipp...