Rated data
Inverter power supply 400 V, forced ventilated motors
Motor
MQA 20L29H MQA 20L14H MQA 22P29H MQA 22P17H MQA 22P14H MQA 22P08H
Degree of protection
IP23
IP23
IP23
IP23
IP23
IP23
Standstill torque
M
0
Nm
76.0
76.0
156
156
156
156
Rated torque
M
N
Nm
66.2
71.3
125
130
135
145
Max. torque
M
max
Nm
250
250
500
500
500
500
Rated speed
n
N
rpm
2930
1420
2935
1670
1425
760
Max. speed
n
max
rpm
6500
6500
6500
6500
6500
6500
Rated power
P
N
kW
20.3
10.6
38.4
22.7
20.1
11.5
Standstill current
I
0
A
54.0
27.0
102
59.0
51.0
29.5
Rated current
I
Rated
A
46.9
26.5
86.0
50.3
45.6
27.6
Max. current
I
max
A
188
106
344
201
182
110
Rated voltage
V
Rated
V
360
360
360
360
360
360
Rated frequency
f
Rated
Hz
100
50
100
58
50
28
Moment of inertia
J
kgcm²
171
171
487
487
487
487
Efficiency
η
0.900
0.800
0.900
0.880
0.860
0.770
Stator terminal resistance
R
UV 20
°C
Ω
0.183
0.731
0.089
0.268
0.357
1.072
Stator terminal resistance
R
UV 150
°C
Ω
0.276
1.102
0.134
0.404
0.538
1.616
Mutual inductance
L
H
mH
13.68
57
23.2
23.86
93.3
92.8
Stator leakage inductance
L
1σ
mH
0.493
1.979
0.892
0.895
3.568
3.53
Rotor leakage inductance
L
2σ
mH
0.524
2.103
1.203
1.206
4.813
4.762
Stator resistance
R
1, 20
Ω
0.0915
0.365
0.134
0.134
0.536
0.536
Rotor resistance
R
2‘, 20
Ω
0.09
0.361
0.12
0.12
0.477
0.477
Weight
m
kg
63.0
63.0
102
102
102
102
Technical data
Rated data
Inverter power supply 400 V, forced ventilated motors
33