Feedback and temperature monitoring connection
ICN-M23 connector assignment
Resolver
1
2
3
4
5
6
7
8
9
10
11
12
P
Code 0°
ICN M23 for resolvers
Contact
Name
Meaning
1
+Ref
Transformer windings
2
-Ref
Transformer windings
3
+VCC ETS
Supply: Electronic nameplate (Only for motors and inverters that support
this function)
4
+COS
Stator windings cosine
5
-COS
Stator windings cosine
6
+SIN
Sine stator windings
7
-SIN
Sine stator windings
8
Not assigned
9
Not assigned
10
Schirm
Encoder housing shield
11
+
Temperature monitoring: PT1000
12
-
Temperature monitoring: PT1000
ICN-M23 connector assignment
Incremental and SinCos absolute value encoder Hiperface©
1
2
3
4
5
6
7
8
9
10
11
12
P
Code 20°
ICN M23 for incremental and SinCos absolute value encoder Hiperface
Contact
Name
Meaning
1
B
Track B / +SIN
2
A¯
Track A inverse / - COS
3
A
Track A / + COS
4
+UB
5
GND
Mass
6
Z¯
Zero track inverse /-RS485
7
Z
Zero track / + RS485
8
Not assigned
9
B¯
Track B inverse/-SIN
10
Schirm
Encoder housing shield
11
+
Temperature monitoring: PT1000
12
-
Temperature monitoring: PT1000
Electrical installation
Motor connection
Connection via ICN connector
31